MA10/4-SW02
Date: 06.05.2014
Page 15 of 23
Art.No. 87185
Mod. status 422/13
Fig. 3: Signal types for referencing
Information concerning the setting of the reference point
Move the spindle exactly to the position which corresponds to the reference value programmed
before accord. to chapter
. The mechanically mounted reference point transmitter must now be
).
The encoder can be turned without causing any movement of the driving spindle, if you
untighten the clamping ring or coupling. You can now search the index signal of the encoder
(voltage change) by using for example a voltmeter and carry out the adjustment of the reference
point. When the index and reference point transmitter signals are positioned as described in
, the clamping ring and the coupling of the incremental encoder are retightened.
Fig. 4: Referencing setup
Drive
Driving spindle
ref. point
transmitter
Incremental card of the MA10/4
Incremental
encoder
Signal A
Signal B
Index signal
ref. point
transmitter signal
definetely
passive
definetely
passive
definetely
aktive
one
revolution
Type 0
Type I