![Siko LE200 Translation Of The Original Installation Instructions Download Page 23](http://html1.mh-extra.com/html/siko/le200/le200_translation-of-the-original-installation-instructions_1270504023.webp)
LE200
Installation English
LE200 · Date
10.09.2018 · Art.
No.
84882 · Mod.
status
232/18
23
Connection type
•
E1: open cable end
Signal
inverted
Color
inverted with reference
signal Color
GND
black
black
sin
red
red
/sin
orange
orange
cos
yellow
yellow
/cos
green
green
+UB
brown
brown
index
- - -
blue
/index
- - -
violet
•
E6: 7 or 8 pole plug pin/socket contact (M16)
Signal
inverted
Pin
inverted with reference
signal Pin
GND
1
5
sin
2
1
/sin
3
6
cos
4
2
/cos
5
7
+UB
6
4
index
- - -
3
/index
- - -
8
nc
7
- - -
1. Slip
6
...
10
over outer cable.
2. Strip cable.
3. Turn down screening
11
.
4. Push
5
onto ferrules.
5. Solder cable to
3
(according connection diagram).
6. Open spacer
4
and put it over ferrules, squeeze and push it onto
3
.
Slot and keyway of
3
and
4
must align.
7. Press
6
and
5
together; cut prodruding screening.
8. Push
2
and
7
together and screw.
9. Push
8
into
9
and slide both parts into
7
.
10. Screw
10
and
7
together.
11. Push
1
into
2
.
viewing side =
plug-in side-
plug pin
2
6
5
4
7
3
1
7
6
1
4
2
5
3
8