Fig. 2: Mounting
Fig. 3: Fastening
torque for screws
Fig. 4: Shaft with
feather kex groove
1
Torque support form B
2
Shaft
3
Champ ring screw
4
Grub screw
4.2 Electrical Installation
Destruction of parts of equipment and loss of regulation control
`
Do not disconnect or close live connections.
`
Perform wiring work in the de-energized state only.
`
Use strands with suitable ferrules.
`
Prior to switching on check all mains and plug connections.
`
Switch on operating voltage together with downstream electronics (e.
g., control unit).
Unforeseen actions of the actuator or other devices
The actuator is protected against EMC irradiation and emission (electroma-
gnetic compatibility). Excessive external EMC radiation may trigger unfo-
reseen actuator actions (including destruction of the actuator; the actu-
ator being set in motion; loss of position value) Devices that are not EMC
protected and those operated in direct vicinity to the actuator may be dis-
turbed.
`
Perform wiring work in accordance with the EMC measures IEC 61800-3
`
Check the correct execution of the EMC measures.