EH-500/600 Installation Manual
Page 37
Matching configuration may be of two types:
Identical configuration – exactly same configuration will be copied from the local
to remote system. It can be found for parameters that normally requires
identical configuration for both local and remote units.
For example, Encryption configuration.
Matching configuration – for parameters that require matching but opposite
configuration.
For example, transmit frequency where Tx(local)=Rx(remote) and
Rx(local)=Tx(remote).
3.4
Quick Configuration Wizard
Use the Quick Configuration wizard to configure the basic system parameters. It holds
the basic minimal configuration required to start using the link.
The Quick Configuration wizard should be used for the initial system setup after
installation. For monitoring and advanced configuration, please refer to the dedicated
configuration pages of the Web-Based Management.
To access the Quick Configuration wizard, go to the Quick Config page.
3.4.1
Quick Configuration: Step 1
– System
Figure 3-5 Quick Config Page: Step 1 - System
The first section allows configuring the following parameters:
Name – you can give a name for each system
Date – [YYYY.MM.DD]
Time – [HH:MM:SS]
Click Next to continue.