background image

Flow Measuring Instrument 

Product Line TD 32500 

Operating Manual 

F:

100%

100,00 l/min

А

рхангельск

   (8182)63-90-72   

А

стана   

(7172)727-132   

А

страхань   

(8512)99-46-04   

Б

арнаул   

(3852)73-04-60   

Б

елгород   

(4722)40-23-64   

Б

рянск   

(4832)59-03-52   

В

ладивосток   

(423)249-28-31   

В

олгоград   

(844)278-03-48   

В

ологда   

(8172)26-41-59   

В

оронеж   

(473)204-51-73   

Е

катеринбург   

(343)384-55-89  

И

ваново   

(4932)77-34-06

 

И

жевск   

(3412)26-03-58  

И

ркутск

 (395)279-98-46 

К

азань   

(843)206-01-48   

К

алининград   

(4012)72-03-81  

К

алуга   

(4842)92-23-67   

К

емерово   

(3842)65-04-62   

К

иров   

(8332)68-02-04   

К

раснодар   

(861)203-40-90   

К

расноярск   

(391)204-63-61   

К

урск   

(4712)77-13-04   

Л

ипецк   

(4742)52-20-81 

К

иргизия  

(996)312-96-26-47

 

М

агнитогорск   

(3519)55-03-13   

М

осква   

(495)268-04-70   

М

урманск   

(8152)59-64-93   

Н

абережные Челны  

(8552)20-53-41  

Н

ижний Новгород  

(831)429-08-12   

Н

овокузнецк  

(3843)20-46-81   

Н

овосибирск   

(383)227-86-73   

О

мск   

(3812)21-46-40   

О

рел   

(4862)44-53-42   

О

ренбург   

(3532)37-68-04   

П

енза   

(8412)22-31-16 

К

азахстан  

(772)734-952-31

 

П

ермь   

(342)205-81-47   

Р

остов-на-Дону   

(863)308-18-15   

Р

язань   

(4912)46-61-64   

С

амара  

(846)206-03-16   

С

анкт

-

Петербург   

(812)309-46-40  

С

аратов   

(845)249-38-78   

С

евастополь   

(8692)22-31-93   

С

имферополь   

(3652)67-13-56   

С

моленск   

(4812)29-41-54   

С

очи   

(862)225-72-31   

С

таврополь   

(8652)20-65-13   

Т

аджикистан  

(992)427-82-92-69

 

С

ургут   

(3462)77-98-35   

Т

верь   

(4822)63-31-35   

Т

омск   

(3822)98-41-53   

Т

ула   

(4872)74-02-29   

Т

юмень   

(3452)66-21-18   

У

льяновск   

(8422)24-23-59   

У

фа   

(347)229-48-12   

Х

абаровск   

(4212)92-98-04   

Ч

елябинск   

(351)202-03-61  

Ч

ереповец   

(8202)49-02-64  

Я

рославль   

(4852)69-52-93  

https://sika.nt-rt.ru/

 || 

[email protected]

Summary of Contents for TD 32500

Page 1: ...61 4712 77 13 04 4742 52 20 81 996 312 96 26 47 3519 55 03 13 495 268 04 70 8152 59 64 93 8552 20 53 41 831 429 08 12 3843 20 46 81 383 227 86 73 3812 21 46 40 4862 44 53 42 3532 37 68 04 8412 22 31 1...

Page 2: ...ation of TD 32500 8 5 1 Commissioning 8 5 1 1 Use as directed 8 5 1 2 Connecting TD 32500 8 5 2 Configuration of TD 32500 8 5 2 1 Setting configuration data 9 5 2 2 Programming operating parameters 13...

Page 3: ...every move and keep the pre set sequence Read the section notes on safety with special attention Remember well the signs pictograms and their importance The operating manual is divided into nine chapt...

Page 4: ...modes or activities can be found in the respective passages of this manual Warnings are marked with special signs Caution High temperature This sign points to danger to persons due to high temperature...

Page 5: ...it up for the required measuring function The alarm LED 4 indicates overstepping or falling short of adjusted limit values The electronics are dust and watersplash safe installed in the bayonet ring...

Page 6: ...ate total flow resettable or temperature analogue output 2 Type of analogue output 0 20 mA 4 20 mA or 0 10 V 3 Range of analogue output In mode 0 20 mA or 4 20 mA a current is driven through the worki...

Page 7: ...ion note the following instructions TD 32500 is mounted onto the flow sensor and can be rotated by 180 You can adjust the instrument to the required position by loosening the threaded stud in the adap...

Page 8: ...High temperature If the medium to be measured has reached a very high temperature level then also the piping and TD 32500 are getting hot Avoid any physical contact and do not place temperature sensit...

Page 9: ...The instrument will switch back to measuring operation if you do not press a key within a period of 60 seconds Note When the and key is pressed for longer than 7 seconds the device automatically reve...

Page 10: ...g this code Unauthorized persons can no longer change the set parameters Note If you have forgotten your access code please refer to your local supplier or to SIKA directly 5 2 1 3 Select physical flo...

Page 11: ...the key to YES and confirm with the key Select with the key one of the following units C Celsius degrees F Fahrenheit degrees Confirm the currently displayed unit by pressing the key Continue to confi...

Page 12: ...ument TD 32500 needs to measure the flow With long gate times is the calculated flow signal very precise but flow changes prolong response time With short gate time is the calculated flow signal more...

Page 13: ...reset process 5 2 2 2 Select reset mode for total volume The setting back of the readjustable volume counter by means of the configuration menu could in some specific instances become cumbersome In th...

Page 14: ...n switch it on again for a restart of the instrument 5 2 3 Programming the percentage reading bargraph This program selects the source flow rate total flow resettable or if available temperature as we...

Page 15: ...h with the key to CHANGE VALUE and confirm with the key A cursor appears Set with the key the respective digits of the new end value of the reading range of the bargraph and confirm it with the key Qu...

Page 16: ...total flow resettable or if available temperature the type of alarm minimum or maximum alarm the alarm point and the alarm hysteresis Parameters of alarm 1 and 2 are completely independent from each o...

Page 17: ...Alarm 1 2 The message SET AL 1 2 MIN MAX NO appears Switch with the key to YES and confirm with the key Select with the key MINIMUM ALARM MAXIMUM ALARM Confirm the currently displayed type of Alarm 1...

Page 18: ...m it with the key Quit the configuration menu return to the menu start or continue to configure the successive parameters 5 2 5 Programming analogue output You can only carry out this programming if T...

Page 19: ...onfiguration menu Note If you have selected for the analogue output ANALOG OUT OFF the following programming items of type and range of the analogue output are skipped The analogue output is unoperati...

Page 20: ...ith the key Continue to program the upper limit of analogue output return to the menu start or quit the configuration menu 5 2 5 1 3 Programming the upper limit of the analogue output range The messag...

Page 21: ...menu Press the key until the message SET PULSE DIVIDE NO appears Switch with the key to YES and confirm with the key The message appears VALUE OK together with the last entered factor Switch with the...

Page 22: ...additional optical signal appears as bright alarm LED In the top line of the display depending on configuration will one of the computed measured values such as flow rate total flow or temperature if...

Page 23: ...pper line remains unchanged with the exception of the display of the non resettable volume counter 6 3 Resetting the volume counter total flow In measurement mode the resettable total flow can put to...

Page 24: ...oubleshooting Attention The following table contains remedy actions malfunction cause remedy TD 32500 does not work properly ambient influences e g magnetic fields wrong supply voltage incorrect insta...

Page 25: ...ude of the sensor 50 mVss to 12 Vss Measuring dynamics adjustable measuring rate gate time to 300 ms 500 ms 1000 ms 1500 ms 2000 ms below a sensor frequency of 20 Hz is measuring rate 1 sensor frequen...

Page 26: ...erature C F Operating buttons 2 infrared light reflex buttons screened against outside light Programming protection 1 programmed parameters protected by access code 2 adjustable key lock Alarm output...

Page 27: ...meter 55 mm height rotational up to 180 installed at flow sensor connection with concentric plug and socket M12x1 or multi lead cable protection class IP65 Ambient service temperature 10 to 60 C Mediu...

Reviews: