SIIG AV-GM06Z3-S1 Manual Download Page 16

~ 15 ~ 

 

C3

 

Output C select Input3

 

 

F1

 

Output F select Input1

 

 

H7

 

Output H select Input7

 

C4

 

Output C select Input4

 

 

F2

 

Output F select Input2

 

 

H8

 

Output H select Input8

 

 
 
 
 
 

The SELLER warrants the AV-GM06Z3-S1 v1.2/v1.3 8x8 SDI Router to be free from defects in 

the  material  and  workmanship  for  3  years  from  the  date  of  purchase  from  the  SELLER  or  an 
authorized dealer. Should this product fail to be in good working order within 3 years warranty 
period, the SELLER, at its option, repair or replace the unit, provided that the unit has not been 
subjected  to  accident,  disaster,  abuse  or  any  unauthorized  modifications  including  static 
discharge  and  power  surge.  This  warranty  is  offered  by  the  SELLER  for  its  BUYER  with  direct 
transaction only. This warranty is void if the warranty seal on the metal housing is broken. 

Unit that fails under conditions other than those covered will be repaired at the current price 

of parts and labor in effect at the time of repair. Such repairs are warranted for 90 days from the 
day of reshipment to the BUYER. If the unit is delivered by mail, customers agree to insure the 
unit  or  assume  the  risk  of  loss  or  damage  in  transit.  Under  no  circumstances  will  a  unit  be 
accepted without a return authorization number. 

The  warranty  is  in  lieu  of  all  other  warranties  expressed  or  implied,  including  without 

limitations, any other implied warranty or fitness or merchantability for any particular purpose, 
all of which are expressly disclaimed.   

Proof  of  sale  may  be  required  in  order  to  claim  warranty.  Customers  outside  Taiwan  are 

responsible for shipping charges to and from the SELLER. Cables and power adapters are limited 
to a 30 day warranty and must be free from any markings, scratches, and neatly coiled.   

The  content  of  this  manual  has  been  carefully  checked  and  is  believed  to  be  accurate. 

However, The SELLER

 

assumes no responsibility for any inaccuracies that may be contained in 

this  manual.  The  SELLER  will  NOT  be  liable  for  direct,  indirect,  incidental,  special,  or 
consequential damages resulting from any defect or omission in this manual, even if advised of 
the possibility of such damages. Also, the technical information contained herein regarding the 
AV-GM06Z3-S1 v1.2/v1.3 features and specifications is subject to change without further notice. 

 

 

 

 

Limited Warranty

 

Summary of Contents for AV-GM06Z3-S1

Page 1: ...8x8 3Gbps HD SDI Router P N AV GM06Z3 S1...

Page 2: ...ize the risk of damage to the unit Follow all instructions and warnings marked on this unit Do not attempt to service this unit yourself except where explained in this manual Provide proper ventilatio...

Page 3: ...rces from any of the eight SDI sources to the any eight SDI receivers at the same time This solution is well suited for use in home theater conference room presentation systems or other similar settin...

Page 4: ...c Allows any SDI display to view any SDI source at any time Auto Reclocking The router master can switch every output channels to any SDI inputs by push in button IR remote controller or RS 232 contro...

Page 5: ...on IR remote RS 232 IR remote control Electro optical characteristics 25 Carrier frequency 38kHz RS 232 connector DE 9 9 pin D sub female Mechanical AV GM06Z3 S1 Housing Metal case Dimensions L x W x...

Page 6: ...5...

Page 7: ...sh buttons Used to input source and display channel number 4 IR IR receiver Rear Panel 5 AC Power 100 240V 6 RS 232 RS 232 control port 7 SW1 firmware update 8 Digital I O Control Singal 9 Sync In Ext...

Page 8: ...7 11 INPUT 1 8 SDI inputs 12 OUPUT PORT 1 8 SDI outputs...

Page 9: ...of the AV GM06Z3 S1 2 Set the pin 1 and pin 2 of SW Main at ON for firmware update mode 4 Power on the AV GM06Z3 S1 The firmware update program should begin this update sequence automatically If not...

Page 10: ...1 1 Connect all sources to SDI Inputs on the 8x8 SDI Router 2 Connect all outputs to SDI Receiver 3 Connect the AC power supply to the 8x8 SDI Router 4 Power on the 8x8 SDI Router AV GM06Z3 S1 Hardwar...

Page 11: ...port Or you can use up and down button to enter IR control mode and select the output port in ascending and descending order respectively Note F1 SDI output port 1 F2 SDI output port 2 F3 SDI output...

Page 12: ...11 Left button to switch input source in descending order 1 8 7 6 5 4 3 2 1...

Page 13: ...nu 1 Scan button Serial Port Scan Press Scan button the machine will scan the all com port and show them Select the RS232 serial port connected to the machine And set device ID 255 is for all device R...

Page 14: ...ct set all output then select the source on main menu You can quickly set all output to the same source Unselect All Output Release output selection Select Input1 8 Output Select Input Source Then sel...

Page 15: ...t Input6 A3 Output A select Input3 D1 Output D select Input1 F7 Output F select Input7 A4 Output A select Input4 D2 Output D select Input2 F8 Output F select Input8 A5 Output A select Input5 D3 Output...

Page 16: ...is delivered by mail customers agree to insure the unit or assume the risk of loss or damage in transit Under no circumstances will a unit be accepted without a return authorization number The warran...

Page 17: ...16 April 2018 Support For more info or tech support http www siig com support...

Reviews: