SPECIFICATIONS 

 

Model Name 

AV-GM03K3-S1 (TX) 

AV-GM03K3-S1 (RX) 

Technical

 

TX 

RX 

TX 

RX 

Role of usage 

Transmitter [TX] 

Receiver [RX] 

Transmitter [TX] 

Receiver [RX] 

Transmission length 

Up to 1,000m (1,100yds) [CAT5e] 

Baud rate 

Up to 57.6kbps in cascade mode 

Input 

1x RS-232 

1x RJ-45 

1x RS-232 

1x RJ-45 

Output 

1x RJ-45 

1x RS-232 

1x RJ-45 

1x RS-232 

1x RJ-45 

RS-232 connector 

DE-9 [9-pin D-sub female] 

RJ-45 connector 

WE/SS 8P8C with 2 LED indicators 

DIP switch 

1-pin DIP switch for master/slave connection mode 

Rotary control switch 

None 

8-level rotary switch 

Mechanical

 

TX

 

RX

 

Housing 

Metal case 

Dimensio
ns   
[L x W x 
H] 

Model 

64 x 48 x 26mm [2.5" x 1.9" x 1" ] 

64 x 48 x 35mm [2.5" x 1.9" x 1.4"] 

Packag

270 x 175 x 80mm [10.6" x 6.9" x 3.1"] 

Carton 

450 x 370 x 300mm [1'6" x 1'3" x 11.8"] 

Weight 

Model 

174g [6.1oz]

 

174g [6.1oz] 

Packag

750g [26.4oz]

 

750g [26.4oz]

 

Fixedness 

Wall-mounting case upon request 

Power supply 

5V 2A DC 

Power consumption 

1 Watt [max] 

Operation 
temperature 

0~40

C [32~104

F] 

Storage temperature 

-20~60

C [-4~140

F] 

Relative humidity 

20~90% RH [no condensation] 

 

Summary of Contents for AV-GM03K3-S1

Page 1: ...RS 232 over CAT5 Extender P N AV GM03K3 S1...

Page 2: ...sk of damage to the unit Follow all instructions and warnings marked on this unit Do not attempt to service this unit yourself except where explained in this manual Provide proper ventilation and air...

Page 3: ...the serial connection has a fixed communication channel between local and remote sites For the receiver the same source unit as transmitter but on the receiving side the receivers can be cascadable u...

Page 4: ...LED indicators DIP switch 1 pin DIP switch for master slave connection mode Rotary control switch None 8 level rotary switch Mechanical TX RX Housing Metal case Dimensio ns L x W x H Model 64 x 48 x...

Page 5: ...unit 3 Connect your CAT 5 5e 6 cable between the transmitting and receiving units 4 Make sure your CAT 5 5e 6 cable is tightly connected and not loose 5 Plug in 5V DC power cord to the power jack of t...

Page 6: ...5 DIP SWITCH DIP SWITCH Position AV GM03K3 S1 point to point connection Master Slave...

Page 7: ...OFF position Master MASTER 1 Move pin to ON position 1 Move pin to ON position Point to multipoint connection Master Slave 1 Move pin to ON position 1 Move pin to OFF position Slave Slave 1 Move pin...

Page 8: ...would like to establish a successful communication channel or change the baud rate correctly the initial communication rate should be 9600 bps Turning off and on receiving units will bring the baud r...

Page 9: ...number The warranty is in lieu of all other warranties expressed or implied including without limitations any other implied warranty or fitness or merchantability for any particular purpose all of wh...

Reviews: