background image

 

 

IMPORTANT: 

FOR YOUR PROTECTION, YOU MUST CAREFULLY READ ALL WARNINGS AND INSTRUCTIONS IN THEIR ENTIRETY  PRIOR TO 

INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH, PERSONAL INJURY AND PROPERTY 
DAMAGE.  If  you  do  not  understand  these  warnings  and  instructions,  or  if  additional  information  is  desired,  please  contact  Signify  at 

[email protected]

 

or phone 800-227-0758. 

Installation, service and maintenance of luminaires must be performed by a qualified professional and in accordance with all federal, state and 
local laws, regulations and electrical codes. This professional should be familiar with the construction and operation of this product and any 
hazards involved. If not qualified, do not attempt installation, service or maintenance.

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts, abrasions and other hazards, please 

read all warnings and instructions included with the luminaire, on the luminaire’s packaging and affixed to the luminaire its

elf.

Maintenance of 

the luminaires should be performed by person(s) familiar with the luminaire’s construction and operation and any hazards 

involved. 

WARNING

 

RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY  

Disconnect or turn off power before attempting any installation, 
service or maintenance.

Verify that supply voltage is correct by referencing the luminaire 
label information.

Make all electrical and ground connections in accordance with
the National Electrical Code (NEC) and any other applicable laws, 
regulations or codes.

All wiring connections should be capped with UL-approved wire 
connectors.

WARNING 

RISK OF FIRE OR PERSONAL INJURY 

Keep combustible materials away from LED/lamp & lens 

Do not operate in close proximity to persons, combustible materials
or substances affected by heat or drying. 

WARNING

 

 RISK OF PERSONAL INJURY 

Wear gloves and safety glasses at all times when removing luminaire
from carton, installing, servicing or performing maintenance.

Avoid direct eye exposure to the light source while it is on.

WARNING

 

RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY

 

Allow LED/lamp & lens to cool before handling. 

Do not touch enclosure or light source

Do not exceed maximum wattage marked on luminaire label.

Follow all manufacturer’s warnings, recommendations, instructions

and restrictions for driver type, burning position, mounting locations
and replacement.

CAUTION 

 RISK OF PRODUCT DAMAGE 

Never connect luminaires and/or components under load with supply voltage turned on.

Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.

Do not restrict fixture ventilation. Allow for some volume of airspace around luminaire. Avoid covering luminaire with insulation, foam or other material that
will prevent convection or conduction cooling.

Do not exceed luminaire maximum ambient temperature.

Do not modify the luminaire.

Only use luminaire in its intended application and location.

LED products are polarity sensitive. Ensure proper polarity before installation.

Electrostatic Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installation and servicing of the luminaire.

Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance.

Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop using it immediately and contact 

[email protected]

 

or phone 800-227-0758. 

Always read the luminaire

s complete installation instructions prior to installation for any additional luminaire specific warnings.

In the case of HID or Fluorescent luminaires, regular re-lamping is required to keep luminaire operating within safe limits

Do not install damaged product.

 Handling and installing damaged products can potentially increase the risks mentioned. In case of damage and/or missing

parts upon arrival of the luminaire, please contac

[email protected]

 

or

 

phone 800-227-0758. 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with 
installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the 

purchaser’s or owner’s purposes, this matter should be referred t

[email protected]

 

or phone 800-227-0758.

 

Please see luminaire specific Installation and Maintenance Instruction for additional warnings or any applicable FCC or regulatory statements. Failure to follow 
any of these Instructions could void luminaire warranties.

Luminaire Maintenance 

Regular luminaire maintenance programs are recommended. 

It is recommended to clean the outside of the luminaire and the refractor/lens. 

Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. 

If clean water is not sufficient for cleaning, use a neutral, synthetic, not-scratching and not-abrasive cleaning 
substance. 

Never use alkaline and/or acetous cleaning substances. 

Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water. 

Signify

 recommends using a cleaning solution that has a PH between 5 and 8.

Recycle: For information on how to recycle electronic products and components, please visit 

www.epa.gov.

WARNINGS AND INSTRUCTIONS FOR LUMINAIRES 

INSTALLATION 

INSTRUCTIONS

442294653951 - REV A

Summary of Contents for Stonco KEENE ASW25-SCT-G1-10-BZ

Page 1: ...Do not restrict fixture ventilation Allow for some volume of airspace around luminaire Avoid covering luminaire with insulation foam or other material that will prevent convection or conduction coolin...

Page 2: ...the specified voltage range of the luminaire shown on the label i e 120 347V Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code...

Page 3: ...ording to the label on the switch the default color temperature is 4000K Switch the dial to the left to 3000K to the right for 5000K or leave it in the middle for 4000K The default power switch is in...

Page 4: ...supply housing Screw 9 Screw the case closed with a screwdriver 10 Install the heatsink assembly and tighten the screws and fixing knob with a screwdriver to complete the installation 8 Install the up...

Page 5: ...ppareil pr voyez de l espace libre autour du luminaire vitez de recouvrir le luminaire avec de l isolant de la mousse ou un autre mat riau qui emp cherait de refroidir l appareil par convection ou con...

Page 6: ...indiqu sur l etiquette ex 120 347V Effectuer tous les connections lectriques et de mise la terre selon les exigences du code de l lectricit national et tous les exigences des codes locales Tous les co...

Page 7: ...t est 4000K Mettez le bouton de r glage gauche pour 3000K et droite pour 5000K Le s lecteur de puissance peut tre mit gauche pour 60W ou 20W d pendant sur le mod le au milieu pour 45W ou 15W ou droite...

Page 8: ...imentation 9 Visser les couvercle en place 10 Installer le dissipateur de chaleur et serrer les vis et le bouton de fixation pour compl ter l installation 8 Installer la partie sup rieur de la compart...