Signify Classified - Internal
page
12/11/2019
3
SLF – Slip Fitter Mount
TULS/TULM/TULL
www.lumec.com
VERTICAL ANGLE ADJUSTMENT
HORIZONTAL ANGLE ADJUSTMENT
aiming sight
HORIZONTAL ANGLE ADJUSTMENT
8.
Secure the luminaire on the tenon. Using a
5/32"
Allen wrench, hand tighten the Slip fitter set screws until
the tip of the screws engage the tenon. (Do not fully tighten). Using the built-in aiming sight at the top edge of
the luminaire rotate the luminaire horizon-tally until the desired aiming target is centered in the aiming
window. Tighten the set screws to 11 ft.-lbs when the final horizontal position is set.
9.
Make electrical connections per Electrical Connection steps 1, 2, 3 and 4 (pg. 2).
VERTICAL ANGLE ADJUSTMENT
NOTE
: Angle adjustment can be made before luminaire installation.
10.
After the luminaire is installed, the vertical angle of the luminaire can be adjusted within the limits of the
aiming diagram (pg.2) in 5
° increments.
11.
To adjust the vertical angle, loosen the 1/2–
13 X 1.75” socket cap bolt located in slip fitter Arm. (Do NOT
remove bolt.) Loosen only enough to allow rotation of cast teeth.
12.
Using the aiming sight and the degree indicators shown as a guide, rotate vertically the luminaire to the
desired position and retighten the bolt loosened in Step 11 to 47 ft.-lbs.
47 ft.-lbs
Installation instructions