background image

Site & Area 

 

Form 10 Square & Round 

EH14,19; CA/MA17,22

 

2/20/2020 

page 1 

www.gardcolighting.com 

 

                                PN 442295163171  Rev B

 

       

 

INSTALLATION PROCEDURE 

1. 

Place pole base edge on the concrete base close to the projecting anchor bolts so that 
the pole can be raised into position with the luminaire properly oriented. 

2. 

Place saw-horse or similar support under pole near the top end so that pole top is 
sufficiently raised to allow for easy mounting of luminaire.  NOTE: Poles are pre-drilled 
with holes for arm mounting. 

3. 

Remove pole cap. 

4. 

Pull field wiring leads through pole leaving sufficient leads above the pole to make 
connections in the pole. 

5. 

Place pole bolster plate over three holes near inside top of pole with tapped hole at 
bottom. (See Fig. 1.) 

6. 

Thread short tie rod into lower tapped hole in pole bolster plate. (See Fig. 1.) 

7. 

Slip gasket and supporting arm over the tie rod projecting from the pole and secure 
with lockwasher and hex nut using an open end wrench through the hand hole in the 
arm. (See Fig. 2.) 

8. 

Thread the long and the medium tie rods into the luminaire end. (See Fig. 1.)  Place 
gasket over rods and luminaire leads. Guide rods through the appropriate tracks in the 
extruded aluminum arm and pull luminaire leads into the arm and through the center 
hole of the pole. Slip long tie rod through clearance hole in the pole and bolster plate 
and secure with hex nut and lockwasher. Secure the medium tie rod to the supporting 
arm with hex nut, flat washer, and lockwasher using an open end wrench through the 
hand hole.    (See Fig. 2.)  

9. 

Level luminaire and torque nuts to 25ft. lbs. 

10. 

Splice field wires to luminaire leads in pole (input and grounding) and tie with strain 
relief on bolster plate.  (See Fig. 3) 

11. 

Replace cover plate. 

12. 

Replace pole cap. 

13. 

If product is using non-comfort pixilated light engines, make sure reflector is oriented 
properly for your application.  The page entitled “Servicing Procedures” explains how 
to remove or re-orient reflector and lens. 

14. 

Installing photocontrol (where applicable). Loosen two screws on top of photocontrol 
receptacle and rotate receptacle until “North” arrow on receptacle points North. Make 
sure receptacle is centered in its mounting hole, tighten screws, and install photocon-
trol. 

NOTE:  It is not necessary to open up the luminaire except for changing reflector        
orientation. Instructions for future servicing are shown on opposite side of this sheet. 

COVER PLATE 

SHORT TIE ROD 

GASKET 

POLE BOLSTER PLATE 

POLE CAP 

SUPPORT ARM 

HEX NUTS 

LOCK WASHERS 

FLAT WASHERS 

LONG TIE ROD 

MEDIUM TIE ROD 

GASKET 

POLE 

NOTE: A square pole is shown for illustration purposes.  Installation procedures to 
round poles are the same except the arm provided is radiused at the pole end. 

Fig. 1 

Fig. 2 

WIRE CONNECTIONS 

Once luminaire is installed and hardware  

is properly torqued, make supply wiring  

connections according to the appropriate  

wiring diagram.

 

* 0-10V AND OVERRIDE WIRES OPTIONAL

 

Fig. 3 

EH14,19 HOUSING 

               OR 

CA/MA17,22 HOUSING 

Summary of Contents for GARDCO EH14

Page 1: ...lockwasher Secure the medium tie rod to the supporting arm with hex nut flat washer and lockwasher using an open end wrench through the hand hole See Fig 2 9 Level luminaire and torque nuts to 25ft l...

Page 2: ...Ensure that reflector hinges on the correct side for your application See Fig 8 below for light direction example Loosen 4 8 32 screws captive and carefully allow reflector assembly to hinge down 90...

Page 3: ...or frame This will free one hinge pin from luminaire housing allowing door to be removed When replacing lens make sure it hinges on the opposite side than the reflector hinges Reflector After opening...

Page 4: ...ghting application Ensure that reflector is orientated in the correct position for your application See Fig 8 for light direction example Loosen 4 8 32 screws and carefully rotate reflector assembly c...

Page 5: ...rondelle plate et une rondelle de blocage l aide d une cl ouverte travers le trou de la main Voir Fig 2 9 Mettez le luminaire et les crous de serrage la position de 25 pi lb 10 pissez les fils sur le...

Page 6: ...se penche sur le c t appropri pour votre application Voir la Fig 8 ci dessous pour un exemple de direction de l clairage Desserrez les 4 vis n 8 32 imperdables permettant l ensemble r flecteur de se r...

Page 7: ...met de retirer la porte Lors du remplacement de la lentille assurez vous qu elle repose sur le c t oppos aux charni res du r flecteur R flecteur Apr s l ouverture ou le retrait de la porte de la lenti...

Page 8: ...raire pour d gager les fentes de trou de serrure Laissez le r flecteur descendre juste assez pour d gager les t tes de vis et faites pivoter l assemblage la position d sir e Assurez vous que les fente...

Reviews: