DocNo.DCP0001330  RnB  25/02/04  rev2 

Installation 

 

Unpacking 

Upon receipt of shipment, please inspect for any damage incurred in transit.  If damage is 

found, please notify your local representative and the transport company immediately.  State date, nature of 
damage and whether any damage was noticed on the shipping container prior to unpacking.  Please give the 
waybill number of the shipping order. 
The unit should not be placed in areas; 

with poor ventilation 

exposed to direct sunlight 

with high ambient temperature or adjacent to heat generating equipment 

with high humidity or dust levels 

susceptible to vibration 

Operation 

 
The 1ZDM has been designed to offer a simple microphone input to the network, with the choice of either local 
operation or global all call operation.  This function is selected on set up of the network system.  This unit can 
also be used in the SigNET LinX voice alarm systems. 
The microphone console comprises of a gooseneck, microphone, speak bar, VU Meter, and two status 
indicators, one for OK and one for fault. 
In order to page, the thumb switch on the microphone or the speak bar are pressed, and if the system is able 
to accept paging, the speak bar will light solid green and paging may commence. 
The speak bar LED indicator will flash if there is a busy input indicating that an equal or higher priority input to 
the system is in use on one of the selected zones, or that access to one of the selected zones is excluded.  If 
the zone selection is valid, the busy in will permit the speak bar to illuminate steadily and the announcement 
can be made. 

Fault monitoring 

 
The electret microphone capsule is monitored for impedance and current absorption.  Any deviation from pre-
set windows triggers the monitor circuit with the following results: 

1.  The OK LED is extinguished and the Fault LED illuminated. 
2.  The monitor circuit removes the 6K8 termination of the PTT.  This puts an open circuit condition on the 
     PTT line, signalling a fault to external control equipment. 

The audio lines are monitored by the phantom detect circuit which notifies any loss of the 15V phantom (due to 
an open circuit or short circuit line) to the monitor circuit.  The monitor circuit causes an open circuit condition 
to be set on the PTT, signalling a fault to signalling a fault to external control equipment. 

DC power operation 

 

The 1ZDM requires a 24V DC supply which enters the unit through the six core cabling (see page 

5

). 

Caution 

This unit must never be directly connected into a 230V AC power supply

.

 

 