Signet 2537 Flowmeter

  

P-Set

This function is available on 
these versions of the 2537:

T

P

t

t

T

P

t

P

T

t

T

P

PULSE TOTAL Output = Input pulses ÷ (K-Factor • P-Factor)

TOTAL is a traditional pump pulser function.  This selection will 
allow the entry of a K-Factor to de

fi

 ne a volumetric unit, then set 

a P-Factor to de

fi

 ne the number of volumetric units required to 

generate one pulse out.

2s

2s

t

T

P

t

T

P

T

P

t

1.

3.

2.

2s

Go to next
menu item

Return to
Normal Operation

Save the new setting:

P-Factor

Minimum value

Maximum value

This function is available on 
these versions of the 2537:

2s

x2

x4

2s

t

T

P

t

P

T

T

P

t

1.

4.

5.

3.

2.

T

P

t

t

T

P

t

P

T

t

T

P

In PULSE DIVIDER mode the P-Factor divides:

The pulse stream from the paddlewheel sensor will be divided 
by the P-Factor.  The resulting frequency is output through a 
relay.

In PULSE TOTAL mode the P-Factor multiplies:

The pulse stream from the paddlewheel sensor is divided 
by the K-Factor MULTIPLIED by the P-factor.  The resulting 
frequency is output through a relay.

2s

Go to next
menu item

Return to
Normal Operation

Save the new setting:

Select DIVIDER or TOTAL operation.
The factory setting is TOTAL.

PULSE DIVIDER Output   = Input pulses ÷ P-Factor

DIVIDER allows you to set a scaling value (P-Factor) from 
1.0000 to 99999.

Example:  If the P-Factor is set for 2, then the 2537 will output 
one pulse for every 2 pulses received from the sensor.
This selection enables the output frequency to be scaled down 
to match associated equipment capabilities.

When using the PULSE DIVIDER output, associated equipment 
must divide the K-factors in this manual by the P-Factor for 
correct calibration.

 Pulses IN

 Pulses OUT

1

2 3

5

7

9

11

4

6

8

10

12

1

2

3

4

5

6

Example:
Set the Total Pulse output so there is one pulse out for each 2 
gallons that passes the sensor if the K-factor is 3.0.

1. 

(K) Factor = 3.0 (pulses in per gallon)

2. 

 P- Factor = 2 (gallons out per pulse)

Pulses IN

Pulses OUT

2

1

3

5

4

6

8

7

9

11

10

12

2

2 Gal

3 Gal

The factory setting is 1.0000

1

1 Gal

4 Gal

Summary of Contents for 159 001 291

Page 1: ...ental Requirements Enclosure rating NEMA 4X IP65 Storage Temperature 10 C to 75 C Ambient Temperature 0 C to 65 C Relative Humidity 0 to 90 RH non condensing Altitude 2000 m 6562 ft Pollution Degree 2 Output specifications Signal Averaging Programmable 0 to 100 seconds Sensitivity Response Programmable 0 to 9 scale Pulse divider Total pulse output Pulse Divider Setting 1 0000 to 99999 Maximum puls...

Page 2: ...allation fittings that control the position of the paddlewheel in relation to the dimensions of the pipe Type Description 2 to 4 inch cut 1 7 16 inch hole in pipe Over 4 inch cut 2 1 8 inch hole in pipe 0 5 to 4 inch versions PVC or CPVC 2 to 4 inch cut 1 7 16 inch hole in pipe 6 to 8 inch cut 2 1 8 inch hole in pipe Iron Carbon Steel 316 SS Threaded tees Carbon steel stainless steel Weld on Weldo...

Page 3: ...For conduit installations Thread conduit with in NPT threads directly into the conduit port For conduit with ISO threads use the black thread adapter included with the connector kit To comply with NEC requirements do not use any metal conduit in the installation 2537 Paddlewheel Flowmeter for in to 4 in pipe 130 mm 5 12 in 97 mm 3 82 in 2537 Paddlewheel Flowmeter for 5 to 8 in pipe 171 mm 6 73 in ...

Page 4: ...elay may be a dry contact type or a solid state type The dry contact relay requires an external power source of 24 VDC 10 The solid state relay requires an external power source of 5 to 24 VDC S1 S2 Power Supply 24 VDC 0 03 A Normally Closed Common Normally Open Blk Red Shld Internal sensor connections S1 S2 Power Supply 5 24 VDC 0 03 A No Connection Blk Red Shld 1 2 Load S1 S2 Blk Red Shld t T P ...

Page 5: ...IZED 0000 0 to 6400 0 page 9 4 Set Set flow RATE to be represented by 4 mA 0 0000 to 99999 page 6 20 Set Set flow RATE to be represented by 20 mA 0 0000 to 99999 page 6 Contrast Adjust visibility of liquid crystal display 1 to 3 page 6 Operation The 2537 Flowmeter is available in 4 different models The programming menus vary significantly from one model to another This chart is provided inside the...

Page 6: ...rn to Normal Operation Save the new setting Select the volumetric units for the flow measurement Flow Units Example Set the Flow Units to Gallons per minute This function is available on these versions of the 2537 2s 2s T P t T P t T P t T P t 1 2 3 Liters minute Factory setting Liters hour Liters day Liters second Gallons minute Gallons hour Gallons day Gallons second 2s Go to next menu item Retu...

Page 7: ...nction is set to zero seconds AVERAGING only AVERAGING and SENSITIVITY Averaging and Sensitivity Settings Because ideal flow conditions are often impossible to achieve the flow rate is often erratic which causes any control features ie relays 4 20 mA loops etc that are associated with the flow rate to be erratic The best solution to these problems is to correct any piping deficiency that causes th...

Page 8: ...heel sensor is divided by the K Factor MULTIPLIED by the P factor The resulting frequency is output through a relay 2s Go to next menu item Return to Normal Operation Save the new setting Select DIVIDER or TOTAL operation The factory setting is TOTAL PULSE DIVIDER Output Input pulses P Factor DIVIDER allows you to set a scaling value P Factor from 1 0000 to 99999 Example If the P Factor is set for...

Page 9: ...ate reaches the setpoint the 2537 will wait this long in seconds before triggering the alarm The factory setting is 0000 0 seconds 4 Program the DELAY A HI alarm will be activated when the flow rate rises ABOVE the setpoint A LO alarm will be activated when the flow rate falls BELOW the setpoint The factory setting is Hi gh x4 2s 2s T P t T P t t T P 1 2 3 4 1 Select HI or LO Relay Alarm logic 2s ...

Page 10: ...N COPPER PIPE SCH K 1 2 CUKT005 917 84 242 50 3 4 CUKT007 428 27 113 15 1 CUKT010 256 43 67 749 1 1 4 CUKT012 176 44 46 615 1 1 2 CUKT015 115 69 30 565 2 CUKT020 63 385 16 746 COPPER TEE FITTINGS ON COPPER PIPE SCH L 1 2 CUKT005 858 22 226 74 3 4 CUKT007 385 74 101 91 1 CUKT010 241 64 63 841 1 1 4 CUKT012 170 90 45 152 1 1 2 CUKT015 112 03 29 598 2 CUKT020 61 74 16 310 PIPE SIZE IN FITTING 2536 85...

Page 11: ... 1 7052 DN 200 SFMT080 4 0720 1 0758 PVC FITTINGS DIN ISO EUROPE ONLY DN 15 PVMT005 972 37 256 90 DN 20 PVMT007 485 69 128 32 DN 25 PVMT010 297 27 78 540 DN 32 PVMT012 170 25 44 980 DN 40 PVMT015 103 71 27 400 DN 50 PVMT020 59 500 15 720 DN 65 PVMT025 34 973 9 2400 DN 80 PVMT030 24 981 6 6000 DN 100 PVMT040 16 275 4 3000 DN 150 PVMT060 8 1756 2 1600 DN 200 PVMT080 4 0878 1 0800 Maintenance and Cle...

Page 12: ...ulse Divider via Dry Contact Relay Integral Mount 3 2537 2C T0 159 001 316 Pulse Divider via Solid State Relay Integral Mount 3 2537 3C T0 159 001 317 Flow Switch via Dry Contact Relay Integral Mount 3 2537 4C T0 159 001 318 Flow Switch via Solid State Relay Integral Mount 3 2537 5C T0 159 001 319 Digital S3L Integral Mount 3 2537 6C T0 159 001 320 4 20 mA Integral Mount Accessories Mfr Part No Co...

Reviews: