2
Knox Waterfall Tub Spout with Hand Shower Installation Instructions
INSTALLATION:
1. Install hot and cold 1/2" female IPS water supplies
in the wall with a 5-3/4" distance between them.
2. Unscrew the M4 screws and loosen the M6 screws
from the faucet body. Remove the leveling plate
and offset connectors.
3. Measure the thread depth of the pipe joints with
your ruler. Your fittings should be flush with the
finished wall.
4. Wrap the offset connectors with teflon tape.
5. Place the offset connectors through the leveling
plate and screw them into the pipe joints. Tighten
slightly wtih the 12mm hex wrench.
6a. Adjust the offset connectors with the 12mm hex
wrench until the plate is level.
Cold Water
Pipe Joint
Hot Water
12mm Wrench
5-3/4"±1/2"
Faucet Body
M6 Screw
Offset
connector Plate
M4 Screw
Leveling