denotes not to control the ingress port rate of the port.
¾
Ingress rate
:
there are 12 different rates from “64K” to “80M” for 100M port,.You can choose
the rate only when the “Ingress Control” is “Enable”.
¾
Egress Control: “Enable”denotes to control the Egress port rate of the port,“Disable” denotes
not to control the Egress port rate of the port.
¾
Egress rate
:
there are 12 different rates from “64K” to “68M” for 100M port. You can choose
the rate only when the “Egress Control” is “Enable”.
Illumination
:
¾
This page provides quick-change function for 100M ports. Select “Enable”, and select the
rate, then press “Change”, all the port rates of the ports that are enabled the control function
will be changed.
¾
All changes will come effective only after you press “Apply” or “Save”.
¾
You cannot set port rate control for ports in the Trunk group.
4.3.2.8 Storm Control
11111111111111111111111111111111111111111111111111111111111111
Fig 4-23 Broadcast Storm Control (part of ports)
¾
Multicast Storm Control: Control storms caused by group broadcast. Select“Enable”to enable
this control function.
¾
Broadcast Storm Control: Control storms caused by general broadcast. Select“Enable”to
enable this control function.
¾
UL Storm Control
:
the switch broadcasts the packets that it cannot learn the address, you can
enable this function to control such unlearnt address storm.
24