background image

Signamax Connectivity System                                 065-7508  

“Link   Capability”   is   meant   you   can 

choose the port is Auto-Nego. mode or 
Force mode on 100M or 10M.

“Duplex” is meant you can select the 

port   is   full   or   half   duplex   or 
enable/disable the port.

Port Management: Bandwidth Control

“Port No.” is meant to the port number 
you want to configure it.

www.signamax-us.com

www.signamax-eu.com

Summary of Contents for 065-7508

Page 1: ...Signamax Connectivity System 065 7508 Signamax Connectivity Systems 8 Ports Nway Fast Ethernet Web Management Switch Model 065 7508 User s Manual www signamax us com www signamax eu com ...

Page 2: ... operated in a commercial environment This equipment generates uses and radiates radio frequency energy and if not installed and used in accordance with the user s manual may cause interference in which case user will be required to correct the interference at his own expense CE Mark Warning This is a Class B product In a domestic environment this product may cause radio interference in which case...

Page 3: ...tallation and high performance in an environment where traffic on the network and the number of user increase continuously The small compact palm size was specifically designed for small to medium workgroups 065 7508 Switch can be installed where space is limited moreover it provides smooth network migration and easy upgrade to network capacity www signamax us com www signamax eu com ...

Page 4: ...Signamax Connectivity System 065 7508 www signamax us com www signamax eu com ...

Page 5: ...x 200Mbps bandwidth on each port Broadcast storm control Store Forward switching methods IEEE 802 3x flow control for Full duplex Zero Packet Loss Back pressure flow control for Half duplex Non blocking Non head of line blocking full wire speed forwarding Auto learning of networking configurations Status LEDs Power Link Activity Low power consumption Smart plug play All ports support uplink functi...

Page 6: ...Package Contents Before you start to install 065 7508 Switch please verify your package that contains the following items One 065 7508 Fast Ethernet Switch One Power Adapter One CD with User s Manual www signamax us com www signamax eu com ...

Page 7: ...re are 1 8 RJ 45 connectors on the front panel for connecting to servers workstation or other devices 0065 7508 Switch provides 8 10 100Mbps switching ports that could sense the 10 100M speed and negotiate Full Half duplex mode automatically These switching ports allow users connect the Switch to 10Base T and 100Base TX devices Ⅱ Power DC 5V 12V Power adapter www signamax us com www signamax eu co...

Page 8: ...t 10 100Mps Switch LED Status Description No Of LED Power On Power on Power LINK ACT On 10 100Mbps port for connection 8 1 8 Flashing 10 100Mbps for data activating 8 1 8 Ⅳ LED Definitions Power LED On The unit is powered on www signamax us com www signamax eu com ...

Page 9: ...ty System 065 7508 and ready for use Off The unit is powered off LINK ACT LED On The port is ready for 10 100Mbps connection Flashing The data is transmitted or received on the port www signamax us com www signamax eu com ...

Page 10: ...f duplex mode Backpressure Full duplex mode IEEE 802 3x 4 Network Transmission Media 10Base T Cat 3 4 5 UTP STP 100Base TX Cat 5 UTP STP 5 Network Status Monitoring LEDs LINK ACT POWER 6 Buffer Memory 512K bits per device 7 Filter Forward Rate Packet Filtering Forwarding Rates 100Mbps port 148 800pps 9 Power Adapter DC 5V 12V www signamax us com www signamax eu com 10Mbps port 14 880pps 8 MAC Addr...

Page 11: ...r Consumption 4 Watts Max 11 Operating Temperature 0 55 12 Store Temperature 20 90 13 Humidity 10 90 RH Non condensing 14 Dimension L W H 175mm 110mm 25mm 15 Weight 0 28Kg 16 Safety EMI Certificates CE FCC B www signamax us com www signamax eu com ...

Page 12: ...abled Supports port setting for N Way or force mode operation Supports Bandwidth Control on transmission and reception Supports Broadcast Storm Protection Supports Maximum Packet Length 1536 or 1552 Supports Port bases VLAN Supports two priority queues for CoS Supports weighted round robin scheduling for queues Supports Port bases 802 1p Diff serv priority three types of CoS www signamax us com ww...

Page 13: ... Ⅱ Configure Please follow the steps to configure 065 7508 Switch Step 1 Use a twisted pair cable to connect 065 7508 Switch to your PC and power on the Switch Step 2 Set your PC s IP to 192 168 2 xx www signamax us com www signamax eu com ...

Page 14: ...192 168 2 1 site and you will see the login screen Key in the user name and the password to pass the authentication and the user ID and the password is admin IP 192 168 2 1 ID admin Password admin After the authentication procedure the home page shows up www signamax us com www signamax eu com ...

Page 15: ...System 065 7508 Step 4 On the following home page select the configuration by clicking the icon It includes Administrator Port Management VLAN Setting QoS Setting Port Security Logout www signamax us com www signamax eu com ...

Page 16: ...tor Authentication Configuration Change the password or use a new user ID and the password Click Update to confirm the new change and then power off on the Switch to take the new ID and the password effectively www signamax us com www signamax eu com ...

Page 17: ...Signamax Connectivity System 065 7508 Administrator System IP Configuration Change the IP address by typing the new IP and press Update to complete the change www signamax us com www signamax eu com ...

Page 18: ...max Connectivity System 065 7508 Administrator System Status It shows the switch MAC address and you can select Back to the last display or Logout when the time s out www signamax us com www signamax eu com ...

Page 19: ...y System 065 7508 Administrator Load Default Setting to EEPROM Click Load to load the factory default setting change and then reset the switch by power off on to take it effectively www signamax us com www signamax eu com ...

Page 20: ...dministrator Firmware Update Follow the instruction on the screen to update the new firmware The firmware is the latest version please contact with your sales agents to get the new firmware information www signamax us com www signamax eu com ...

Page 21: ...Signamax Connectivity System 065 7508 Port Management Port Control Configuration Port No is meant to the port number you want to configure it www signamax us com www signamax eu com ...

Page 22: ...the port is Auto Nego mode or Force mode on 100M or 10M Duplex is meant you can select the port is full or half duplex or enable disable the port Port Management Bandwidth Control Port No is meant to the port number you want to configure it www signamax us com www signamax eu com ...

Page 23: ... of the selected port and choose the full speed or 128K 256K 512K 1M 2M 4M 8M speed RX Rate is meant you can set the maximum receiving rate of the selected port and choose full speed or 128K 256K 512K 1M 2M 4M 8M speed Port Management Broadcast Storm Control www signamax us com www signamax eu com ...

Page 24: ...Signamax Connectivity System 065 7508 Enable or disable the broadcast storm protection feature Port Management Max Packet Length www signamax us com www signamax eu com ...

Page 25: ...Signamax Connectivity System 065 7508 Select the maximum packet length setting 1536 byte or 1522 byte by the switch VLAN Setting Group VLAN setting www signamax us com www signamax eu com ...

Page 26: ... 065 7508 There are 4 VLAN groups 01 02 03 04 can be used Select a group and then click the port number which you want to put it into the selected VLAN group VLAN Setting Multi to 1 Setting www signamax us com www signamax eu com ...

Page 27: ...nectivity System 065 7508 This is a special design for easily setting the Switch VLAN into VLAN Per Port After this setting all ports can only connect to the destination port www signamax us com www signamax eu com ...

Page 28: ...Signamax Connectivity System 065 7508 QoS Setting Class of Service Configuration Select the class of service for each port www signamax us com www signamax eu com ...

Page 29: ...Signamax Connectivity System 065 7508 QoS Setting High Priority Queue Configuration Select WRR low weight 1 4 or 1 8 www signamax us com www signamax eu com ...

Page 30: ...Signamax Connectivity System 065 7508 QoS Setting Customization Diffserv Please follow the instruction on the screen to update the setting www signamax us com www signamax eu com ...

Page 31: ...hen this function is enabled the port will record the first receiving source MAC address as the security MAC address and only allow the packet which has the MAC address activating on the port Logout Click to logout www signamax us com www signamax eu com ...

Reviews: