Baseband Connections
The SC5412A has four baseband input ports, comprised of differential in-phase (I+ and I-) and
differential quadrature (Q+ and Q-) inputs. Nominal differential input impedance is 100
Ω.
The
modulator can also be configured for single-ended or differential IF input. When configured for single-
ended operation, it is recommended to terminate the other half of the differential pair using a 50
Ω
terminator. All baseband connectors are MCX female.
Indicator LED
The SC5412A provides visual indication of important modes. There is one LED indicator on the unit. Its
behavior under different operating conditions is shown in Table 1.
Table 1. LED indicator states.
LED
Color
Definition
STATUS
Green
“Power good” and
device is ready.
STATUS
Off
Power fault. Contact SignalCore.
ACTIVE
Green/Off
Device is open (green) /closed (off). This indicator is also
user programmable (see register map).