Signal Hound USB-SA44B User Manual Download Page 18

Warranty and Disclaimer |

 

Warranty Service

 

14 

7.2

 

WARRANTY SERVICE 

For warranty service or repair, this product must be returned to Test Equipment Plus.  The Buyer shall 
pay  shipping  charges  to  Test  Equipment  Plus  and  Test  Equipment  Plus  shall  pay  UPS  Ground,  or 
equivalent,  shipping  charges  to  return  the  product  to  the  Buyer.    However,  the  Buyer  shall  pay  all 
shipping  charges,  duties,  and  taxes,  to  and  from  Test  Equipment  Plus,  for  products  returned  from 
another country. 

7.2.1

 

Limitation of Warranty 

The  foregoing  warranty  shall  not  apply  to  defects  resulting  from  improper  use  by  the  Buyer,  Buyer-
supplied  software  or  interfacing,  unauthorized  modification  or  misuse,  operation  outside  of  the 
environmental  specifications  for  the  product.    No  other  warranty  is  expressed  or  implied.    Test 
Equipment  Plus  specifically  disclaims  the  implied  warranties  or  merchantability  and  fitness  for  a 
particular purpose. 

7.2.2

 

Exclusive Remedies 

The remedies provided herein are the Buyer’s sole and exclusive remedies.  Test Equipment Plus shall 
not be liable for any direct, indirect, special, incidental, or consequential damages,  whether based on 
contract, tort, or any other legal theory. 

7.2.3

 

Certification 

Test  Equipment  Plus  certifies  that,  at  the  time  of  shipment,  this  product  conformed  to  its  published 
specifications. 

7.2.4

 

Credit Notice 

Windows® and Excel® are  registered  trademarks  of  Microsoft  Corporation  in  the  United  States  
and  other  countries.  

Summary of Contents for USB-SA44B

Page 1: ...USB SA44B Spectrum Analyzer User Manual...

Page 2: ...Manual 2016 Signal Hound Inc 35707 NE 86th Ave La Center WA 98629 USA Phone 360 263 5006 Fax 360 263 5007 This information is being released into the public domain in accordance with the Export Admini...

Page 3: ...iii Contents 1 Preparing for Use 1 2 Getting Started 2 3 Theory of Operation 7 4 Troubleshooting 8 5 Calibration and Adjustment 9 6 Specifications 10...

Page 4: ...iv 7 Warranty and Disclaimer 13...

Page 5: ...weighing only ten ounces the Signal Hound can be used virtually anywhere 1 1 INITIAL INSPECTION Check your package for shipping damage before opening Your box should contain a USB cable a CD ROM and a...

Page 6: ...exceed 20 dBm or damage may occur A READY BUSY LED flashes orange each time a command from the computer is processed The rear panel has three connectors 1 10 MHz Reference input automatically detecte...

Page 7: ...Getting Started Front Rear Panels 3...

Page 8: ...elatively immune from this effect 3 Two RF input signals spaced by 42 8 MHz will generate a spurious response halfway between the two RF input signals This spurious response will not be present when a...

Page 9: ...settings two preamplifier settings two ADC clock frequencies and three IF gain settings when measuring signals and performing image suppression Unless you explicitly disable the automatic settings th...

Page 10: ...surements The level of the external timebase must be 0 dBm 13 dBm is recommended to achieve optimal phase noise performance To use simply connect the timebase to the Ext Ref In after connecting the US...

Page 11: ...odes I Q streaming This is used for real time mode frequency domain and zero span mode time domain In this mode the USB SA44B continuously mixes a fixed LO frequency with the RF input and streams the...

Page 12: ...1 4 IF and RBW Selection The I Q data comes in over USB and is processed using an FFT with a custom Flat Top window based on the selected RBW Software and firmware limitations only allow certain very...

Page 13: ...may consider using a low phase noise external reference or contacting us about lower phase noise options Be aware that the Signal Hound phase noise is noticably higher than a YIG based spectrum analy...

Page 14: ...ect to external 10 MHz timebase 0 to 20 dBm Frequency Readout Accuracy reference error 1 sample 1 Marker Accuracy reference error 1 sample Resolution Bandwidth 0 1Hz to 250KHz and 5MHz 2 Spectral Puri...

Page 15: ...ference level 0 dBm 0 25 dB Maximum Safe Input Level preamp off 15 dB atten 20dBm DC Volts 0 2V absolute maximum 16VDC option 3 Residual Responses Input terminated 100 KHz span 0 dB atten preamp on 80...

Page 16: ...IF BW 100 KHz to 4 4 GHz 0 dBm to 70 dBm after 10 min warmup 0 25dB Maximum IF Bandwidth 240 KHz Audio Filters Low Pass Digital Windowed Sinc selectable cutoff Band Pass Available in version 2 xx leg...

Page 17: ...and Disclaimer 2015 Signal Hound All rights reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws 7 1 WARRANTY The...

Page 18: ...interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product No other warranty is expressed or implied Test Equipment Plus specifically disclai...

Reviews: