CONTROL PANEL
ETV 0853-3
12.04.2017
Page 25
24
DIV BY 0
A division error has occurred.
Possible Causes:
-
Division by 0.
-
The result of a division does not
fit in the result register.
Solution:
- Correct programming error.
25
DIAS ERROR
An error has occurred while accessing a
DIAS module.
Hardware problem
26
WAIT
The CPU is busy.
Info
27
OP PROG
The operating system is currently being
reprogrammed.
Info
28
OP INSTALLED
The operating system has been rein-
stalled.
Info
29
OS TOO LONG
The operating system cannot be loaded;
too little memory.
Restart; report error to Sigmatek.
30
NO OPERATING
SYSTEM
Boot loader message.
No operating system found in RAM.
Restart; report error to Sigmatek.
31
SEARCH FOR OS
The boot loader is searching for the
operating system in RAM.
Restart; report error to Sigmatek.
32
NO DEVICE
Reserved
33
UNUSED CODE
Reserved
34
MEM ERROR
The operating system loaded does not
match the hardware configuration.
-
Use the correct operating system
version
35
MAX IO
Reserved
36
MODULE
LOAD
ERROR
The LASAL Module or project cannot be
loaded.
Solution:
-
Recompile and download the
entire project
37
BOOTIMAGE
FAILURE
A general error has occurred while
loading the operating system.
Contact SIGMATEK
38
APPLMEM ERROR
An error has occurred in the application
memory (user heap).
Solution:
-
Correct allocated memory access
error
39
OFFLINE
This error does not occur in the control.
This error code is used in the
programming system to show that
there is no connection to the con-
trol.
40
APPL LOAD
Reserved