ETT 764
MULTI-TOUCH OPERATING PANEL
Number
Message
Definition
Cause/Solution
72
S-DIAS ERROR
A connection error with an
S-DIAS module has
occurred.
Possible Causes:
n
Real network does not match
the project, S-DIAS client is
defective
Solution:
n
Analyze log file
75
SRAM ERROR
An error occurred while
initializing, reading or
writing SRAM data.
Possible Causes:
n
SRAM configured incorrectly
n
Battery for powering the internal
program memory is empty
Solution:
n
Analyze log file (Event00.log,
Event19.log)
n
Check configuration
n
Exchange battery for powering
the internal program memory
95
USER DEFINED 0
User-definable code.
96
USER DEFINED 1
User-definable code.
97
USER DEFINED 2
User-definable code.
98
USER DEFINED 3
User-definable code.
99
USER DEFINED 4
User-definable code.
100
C_INIT
Initialization start; the
configuration is run.
101
C_RUNRAM
The LASAL project was
successfully started from
RAM.
102
C_RUNROM
The LASAL project was
successfully started from
ROM.
103
C_RUNTIME
104
C_READY
The CPU is ready for
operation.
105
C_OK
The CPU is ready for
operation.