background image

 

C-DIAS PROCESSOR MODULE 

CCP 531 

12.04.2017 

Page 23 

 

05 

Watchdog 

The program was interrupted through the 
watchdog logic. 

Possible Causes: 

User  program  interrupts  blocked 
over  a  longer  period  of  time  (STI 
command forgotten) 

Programming  error  in  a  hardware 
interrupt. 

INB,  OUTB,  INW,  OUTW  instruc-
tions used incorrectly. 

The processor is defect. 

 

Solution: 

Correct programming error. 

-  Exchange CPU. 

06 

GENERAL 
ERROR 

General error 

 

07 

PROM DE-
FECT 

An error has occurred while programming 
the memory module. 

Cause: 

The  program  memory  module  is 
defect. 

The user program is too large. 

The  program  memory  module  is 
missing. 

 

Solution: 

Exchange  the  program  memory 
module 

08 

Reset  

The  CPU  has  received  the  reset  signal 
and is waiting for further instructions. 

The user program is not processed. 

 

 

09 

WD DEFEKT 

The  hardware  monitoring  circuit  (watch-
dog logic) is defect. 

After  power-up,  the  CPU  checks  the 
watchdog  logic  function.  If  an  error 
occurs  during  this  test,  the  CPU  deliber-
ately enters an infinite loop from which no 
further instructions are accepted.

 

Solution:  Exchange CPU. 

 

10 

STOP 

 

 

11 

PROG BUSYS 

 

 

12 

PROGRAM 
LENGTH 

 

 

13 

PROG END 

The  memory  module  was  successfully 
completed. 

 

14 

PROG MEMO 

The  CPU  is  currently  programming  the 
memory module. 

 

Summary of Contents for CCP 531

Page 1: ...sed as the online interface connection A 7 segment display and 2 status LEDs provide information on the actual status of the CPU For program updates the integrated USB Host interface can be used USB s...

Page 2: ...6 kbyte L2 Cache BIOS AMI Internal program and data memory DDR2 RAM 64 Mbytes Internal remnant data memory 512 Kbytes 1 Internal storage device 512 Mbytes microSD card 12 104 531 1 Gbyte microSD card...

Page 3: ...TEK operating system With such devices Ethernet packets could be sent to the control with such a high frequency i e broadcasts that the high interrupt load could cause a real time runtime error or run...

Page 4: ...1 x Project back up Internally on the microSD card Standard UL508 E247993 Environmental conditions Storage temperature 10 85 C Operating temperature 0 60 C Humidity 10 90 uncondensed EMV stability Acc...

Page 5: ...C DIAS PROCESSOR MODULE CCP 531 12 04 2017 Page 5 Mechanical Dimensions 104 10 dimensioning incl covers 24 90 129 109 2...

Page 6: ...C DIAS PROCESSOR MODULE CCP 531 Page 6 12 04 2017 Connector Layout...

Page 7: ...ery USB stick be tested before actual use Il faut souligner que la plupart des p riph riques USB sur le march ne sont pas conformes aux sp cifications USB ce qui peut entra ner des dysfonctionnements...

Page 8: ...he lifespan of the storage media Il est recommand de n utiliser que les supports de stockage approuv s par SIG MATEK compact flash microSD etc Num ro de commande pour la carte microSD 512 Mo Edge est...

Page 9: ...ing the microSD card The microSD card is located under the LED cover To exchange the microSD card carefully lift the LED cover The microSD card is located on the left side and can be disengaged by lig...

Page 10: ...5 2 ST 3 5 0 13 1 0 mm2 30 16 AWG UL 28 16 AWG CSA 0 22 0 25 Nm Applicable connectors USB Device 5 pin type Mini B USB Host 4 pin type A Ethernet 8 pin RJ45 CAN Bus 6 pin Weidm ller plug B2L3 5 6 Sup...

Page 11: ...Color Description Active Yellow Lights when data is exchanged over Ethernet Link Green Lights when the connection between the two PHYs is established Control LED Color Description ERROR Red Lights wh...

Page 12: ...lay If an error occurs while running the program or no valid user program is found the dis play shows an error message Thereby Er error and the error code are displayed al ternatingly The same error c...

Page 13: ...can be in stalled in a CAN bus system However each station number can only be assigned once CAN bus data transfer rate The data transfer rate baud rate for the CAN bus can be set However the longer th...

Page 14: ...C DIAS PROCESSOR MODULE CCP 531 Page 14 12 04 2017 Configuration of the Process Module...

Page 15: ...ly 1 5 s the menu is accessed and the setting can be changed with short presses Once the desired changes are made press the SET button for about 5 seconds to end the process If the changes are to be d...

Page 16: ...C baud rate 00 615 000 01 500 000 02 250 000 03 125 000 04 100 000 05 50 000 06 20 000 07 1 000 000 I1 I2 I3 I4 IP address I1 I2 I3 I4 Hexadecimal 00 FF respectively S1 S2 S3 S4 Subnet Mask S1 S2 S3 S...

Page 17: ...aused by reflections in the line Device 1 Device 2 Device 3 Device n e g CPU DCP 080 e g Terminal ET 081 CAN Bus Connections CAN Bus termination on terminal module D SUB plug with terminating resistor...

Page 18: ...rovided C DIAS module carrier It is important to cre ate a low ohm earth connection only then can error free operation be guaranteed The earth connection should have the maximum cross section and the...

Page 19: ...the function ESD Protection Before any device is connected to or disconnected from the CCP 531 the potential with ground should be equalized by touching the control cabinet or earth terminal Static el...

Page 20: ...C DIAS PROCESSOR MODULE CCP 531 Page 20 12 04 2017 Process Diagram...

Page 21: ...tem stops at a checkpoint Number Meaning Cause solution 88 Display during system start If the status does not change the oper ating system or application cannot be started This may be for different re...

Page 22: ...rrently being run The display is not affected 02 RUNTIME The total duration of all cyclic objects exceeds the maximum time the time can be configured using 2 system variables Runtime time remaining SW...

Page 23: ...am memory module is defect The user program is too large The program memory module is missing Solution Exchange the program memory module 08 Reset The CPU has received the reset signal and is waiting...

Page 24: ...is in single step mode and is waiting for further instructions 19 Ready A module or project has been sent to the CPU and it is ready to run the program 20 LOAD The program has stopped and is receiv i...

Page 25: ...9 OS TOO LONG The operating system cannot be loaded too little memory 30 NO OPERATING SYSTEM Boot loader message No operating system found in RAM 31 SEARCH FOR OS The boot loader is searching for the...

Page 26: ...ligent DIAS Master 64 INTERNAL ERROR An internal error has occurred all applications are stopped Restart report error to Sigmatek 65 FILE ERROR An error has occurred during a file operation 66 DEBUG A...

Page 27: ...code 99 USER DEFINED 4 User definable code 100 C_INIT Initialization start the configuration is run 101 C_RUNRAM The LASAL project was successfully started from RAM 102 C_RUNROM The LASAL project was...

Page 28: ...be updated 224 LINKING The application is currently linking 225 LINKING ERROR An error has occurred while linking An error messaged is generated in the LASAL status window 226 LINKING DONE Linking is...

Page 29: ...ile the user program is writing to the microSD card this can sometimes lead to partial loss of remnant data The file system does not support safe writing through SRAM If files are stored modified or w...

Page 30: ...user program can have a massive effect on the microSD card lifespan Detailed information regarding the SRAM behavior and the corresponding settings can be found in the LASAL OS documentation in the c...

Reviews: