C-IPC EXPANSION CARD
Ethernet cable connection
Twisted pair cable connection (expansion card to a HUB)
8
1
Both ends of the network cable have this assignment (not cross-linked).
It's badly recommended to use this assignment, otherwise the impedance of the network
cable is incorrect and the maximum cable length of 100 m cannot be reached!
Twisted pair cable connection (expansion card to other Ethernet devices)
8
1
At direct connection without HUB the network cable has to be cross-linked. Therefore both
ends have a different assignment (Tx/Rx cross-linked).
It's badly recommended to use this assignment, otherwise the impedance of the network
cable is incorrect and the maximum cable length of 100 m cannot be reached!
Pin
Function
Cable (both sides)
1
Tx+
Orange
2
Tx-
Orange/white
3
Rx+
Green
4
not assigned
Blue
5
not assigned
Blue/white
6
Rx-
Green/white
7
not assigned
Brown
8
not assigned
Brown/white
Pin
Function (side 1)
Cable (side 1)
Cable (side 2)
1
Tx+
Orange
Green
2
Tx-
Orange/white
Green/white
3
Rx+
Green
Orange
4
not assigned
Blue
Blue
5
not assigned
Blue/white
Blue/white
6
Rx-
Green/white
Orange/white
7
not assigned
Brown
Brown
8
not assigned
Brown/white
Brown/white
16.04.2010 Page