background image

 

SD160

ex

_BA_en_004 

 

 

30 

 

Summary of Contents for SD160ex

Page 1: ...BLZ 672 922 00 Konto 55258007 D 74928 H ffenhardt info sigmann delta de Gesch ftsf hrer S W I F T Code GENO DE 61SSH UstIDNr DE257944309 http www sigmann delta de Joachim Kraus IBAN DE31 6729 2200 005...

Page 2: ...SD160ex_BA_en_004...

Page 3: ...4 Product Information SD160ex 8 4 1 Explosion Protection 8 4 2 Technical Data 8 4 3 Type Numbers 10 4 4 Serial numbers 10 4 5 Application 10 5 System Assembly 1D Sanner 11 5 1 Discritpion 11 6 Produc...

Page 4: ...ction SD160ex SD260ex to SDVM125ex RS232 19 9 4 Connection power supply SDVM125ex USB 20 9 5 Direct Connection SD160ex to SDVM125ex USB 21 10 Attachment 22 10 1 Certificate Wired Handheld Scanner SD16...

Page 5: ...SD160ex_BA_en_004 2 1 Product range wired handheld scanner Zone 1...

Page 6: ...SD160ex_BA_en_004 3 2 Scanner overview Wired Bluetooth 1D PDF 2D SD160ex SD160exPDF SD260ex SD160BTex SD160BTex PDF SD161BTex SD161BTex PDF SD261BTex...

Page 7: ...re highlighted by a special symbol and a different font colour Danger Non compliance may result in life threatening situations This warning must be heeded Warning This type of warning concerns dangero...

Page 8: ...re that they have the most up to date version of the operating instruc tions To be sure this is the case please check Sigmann DELTA s website at www Sigmann DELTA de or contact one of the company s st...

Page 9: ...explosion protec tion is no longer guaranteed Ensure safe handling with firm footing and sufficient room for movement If the enclosure is in any way damaged the device must be removed from the hazardo...

Page 10: ...e light Brief expo sure to a class 2 laser is deemed not dangerous Maintenance Provided the device is operated and assembled according to instructions and the ambient requirements are being met contin...

Page 11: ...V with connection cable SD Z10 0007 XX maximum input voltage Ui 5 6 V maximum input current Ii 480 mA maximum input power Pi 1 25 W maximum internal inductance Li negligible maximum internal capacitan...

Page 12: ...0825 1 Scan rate 500 scans per second Reader distance 50mm to 800 mm 0 5mm Dimensions 104 x 76 x 185 mm length x width x height Ambient temperature 20 C to 50 C Storage temperature 30 C to 70 C Weight...

Page 13: ...RS232 RS422 5 6V Version used with connection cable SD Z10 0007 XX and only for connection to 5 6V power supply SD 211 X001 XX SD 112 0000 01 Standard 1D Stacked PDF RS232 RS422 4 9V Version used wit...

Page 14: ...r supply and a PC External connection cable Data cable USB 0 2 2 5 mm2 4 wire or RS232 0 2 2 5 mm2 3 wire Power supply cable 0 2 2 5 mm2 3 wire The Bluetooth handheld scanner the base charging station...

Page 15: ...IIIC T135 C Db Certification IBExU 12 ATEX 1120 IECEx IBE 15 0016 Manufacturer Sigmann DELTA GmbH Hauptstra e 53 74928 H ffenhardt Germany 6 2 Technical data Typ SD 115 0000 00 RS232 4 9V connection...

Page 16: ...0 13mm Dimensions 104 x 76 x 185 mm length x width x height Ambient temperature 20 C to 50 C Storage temperature 40 C to 70 C Weight ca 200 g without connection cable Nominal data Operating voltage U...

Page 17: ...th connection cable SD Z10 000X XX 6 4 Serial numbers Serial key year of manufactur serial number 2 numbers 4 numbers Example 130001 6 5 Application The scanner is a handheld device Its purpose is por...

Page 18: ...ly and a PC External connection cable Data cable USB 0 2 2 5 mm2 4 wire or RS232 0 2 2 5 mm2 3 wire Power supply cable 0 2 2 5 mm2 3 wire The Bluetooth handheld scanner the base charging station and t...

Page 19: ...en_004 16 8 Cable range in System Assembly with SD160ex and SD260ex RS232 SD160ex SD260ex 1 8m or 3 8m or optional with 4 5m or 6m extension SD125ex Up to 20m Host USB SD160ex 1 8m or 3 8m SD125ex Up...

Page 20: ...eld scanner with the power supply Make sure the plug has engaged fully Cable SD Z10 0008 XX RS232 SD Z10 0009 XX USB connected to the handheld scanner SD160ex SD 112 0000 0X or cable SD Z10 0008 XX RS...

Page 21: ...he enclosure has been closed fully and all screws have been tightened Cables may only be connected by trained staff Pin assignment of the plug connector and the pin assignment of the direct connection...

Page 22: ...0 connection with cable end sleeve Pin assignment Wired handheld scanner SD160ex SD260ex RS232 connection cable SD Z10 0008 0X Power supply RJ45 Pin assign ment Wire colours Definition Connection term...

Page 23: ...to ensure that the enclosure has been closed fully and all screws have been tightened Cables may only be connected by trained staff Pin assignment of the plug connector and the pin assignment of the d...

Page 24: ...cable end sleeve Pin assignment Wired handheld scanner SD160ex UBS connection cable SD Z10 0009 0X Power supply RJ45 pin assign ment Wire colours Definition Connection terminal power supply Definition...

Page 25: ...SD160ex_BA_en_004 22 10 1 EC type examination certificate SD160ex 10 Attachment...

Page 26: ...SD160ex_BA_en_004 23...

Page 27: ...SD160ex_BA_en_004 24...

Page 28: ...SD160ex_BA_en_004 25...

Page 29: ...SD160ex_BA_en_004 26 10 2 Certificate of Conformity SD160ex...

Page 30: ...SD160ex_BA_en_004 27...

Page 31: ...SD160ex_BA_en_004 28...

Page 32: ...SD160ex_BA_en_004 29 10 3 EC type examination certificate SDVM125ex...

Page 33: ...SD160ex_BA_en_004 30...

Page 34: ...SD160ex_BA_en_004 31...

Page 35: ...SD160ex_BA_en_004 32...

Page 36: ...SD160ex_BA_en_004 33...

Page 37: ...SD160ex_BA_en_004 34...

Page 38: ...SD160ex_BA_en_004 35 10 4 Certificate of Conformity SDVM125ex...

Page 39: ...SD160ex_BA_en_004 36...

Page 40: ...SD160ex_BA_en_004 37...

Page 41: ...SD160ex_BA_en_004 38...

Page 42: ...SD160ex_BA_en_004 39...

Page 43: ...SD160ex_BA_en_004 40...

Page 44: ...SD160ex_BA_en_004 41...

Page 45: ...SD160ex_BA_en_004 42 Sigmann DELTA GmbH Hauptstra e 53 D 74928 H ffenhardt Tel 49 0 6268 92899 73 Fax 49 0 6268 92899 74 info sigmann delta de www sigmann DELTA de 11 Contact...

Reviews: