background image

Instruction Manual for SGP Dual Head Pneumatic Filler 

 

 

-4-

 

Chapter 2 Operation Instruction   

2-1  Preparation   

1.  Precautions   

(1)  The inlet air pressure should be 0.5-0.8Mpa and the working air pressure should be 0.4-0.5 Mpa.   

(2)  Keep all appendages clear of moving parts during operation.                                 

 

2.  Filling amount troubleshooting   

Adjust the filling amount as follows:   

(1)  Put materials to be filled into the container.   

(2)  Prepare measuring cup or scale to identify quantities desired.   

(3)  Turn the hand wheel to adjust the variable sensor to desired range.   

(4)  Check to ensure that the operation switch is set to Semiautomatic, use the foot pedal to control the cycle, 

measure the obtained product to see whether it is in the desired quantity. If not, proceed by the 

following: 

A

 

Loosen the locking handle on the adjustable sensor.   

B

 

Turn the hand wheel clockwise or counterclockwise.   

C

 

Repeat step 4, using a measuring cup or bottle to measure the materials and adjust the handwheel until 

the obtained result is within the desired range.   

D

 

Tighten the locking handle on  the adjustment sensor to avoid parts shifting and influencing the filling 

accuracy.        

2-2  Operation Method   

(1)  Connect the air source and slide the air inlet collar towards the machine.   

(2)  Check whether the air pressure meter is in the specified range (roughly reading in the “12-3 o’clock” 

range). If not, draw the air pressure knob outwards to unlock, rotate the pressure regulator knob until the 

pressure is in the specified range (0.4-0.5Mpa) and push the knob back in to lock. 

(3)  Use the Auto/Semiauto switch to set the filler to the desired operation method. 

(4)  To make an adjustment, you can loose the locking handle on the adjustment sensor, rotate the 

handwheel, take note of the value on the position display and fasten the handle. 

(5)  Adjust the front valve (for adjusting drawing speed) and behind valve (for adjusting filling speed) as 

shown in Figure 1 to get reasonable drawing and filling speed.   

Reviews: