   SETTING HOT LIMIT STOP

IT IS THE RESPONSIBILITY OF THE INSTALLER TO SET THE MAXIMUM OUTPUT TEMPERATURE OF THE VALVE AS SPECIFIED BY 

THE AUTHORITY HAVING JURISDICTION IN ACCORDANCE WITH ASSE/ANSI 1016-2005 4.2.2 REQUIREMENTS.

     thermometer or calibrated sensing device to accurately measure the outlet water temperature. 
2.  Turn off the water using both screw driver service stops.
3.  Expose the top of the cartridge by removing the top hex cap from the valve body. FIG. 2
4.  Remove the temperature ring by placing the blade of a knife into the groove and 
     prying it off.  FIG. 3. It is not necessary to remove the inner hex nut.      
5.  Locate the stop tab on the bottom of the ring. The further it is re-oriented in a counter-clock    

     vary and water supply temperatures vary as well.
6.  

IMPORTANT!!  BEFORE RE-ORIENTING THE RING, BE SURE THE STEM IS IN THE FULL OFF 

POSITION.

     maximum hot water temperature.

FIG. 2

FIG. 3

HEX CAP

TEMPERATURE 

RING

1.  Install extended stem and all thread onto cartridge stem. Fully seat stem onto cartridge by tightly securing all 

     thread nipple and locking nut onto valve. Install plate and centering nut. FIG 4a.

     to extend. FIG 4b.

3.  Place handle on stem and measure excess between escutcheon and handle base. Remove handle and cut 

     excess from end of stem using cut marks provided. FIG 4c.

4.  

FOR TUB/SHOWER TRIM:

REPLACEMENT PARTS:

18.30.893     Cartridge

18.30.894     Diverter Cartridge

18.30.891     16 pt. stem extension

18.30.892     20 pt. stem extension

18.30.890     All thread

FIG. 4c

Cut this distance

from end of Stem Extension

so handle sits just above

the escutcheon

Gap

Handle

Stem Extension

Diverter Handle Sleeve

Diverter Handle Stem and Sleeve

thread directly onto Valve Extension

FIG. 4a

Trim Plate

Trim Plate Centering Nut

(not used on all handle trim)

FIG. 4b

Cut All-thread Flush with

top of escutcheon

Escutcheon

All-thread

Cut

INSTALLING TRIM

Summary of Contents for 18.30.061

Page 1: ...e valve in use They are not to be used INLETS 6 Shower valve Part 18 30 061 or Part 78 30 061 may be used for shower only or tub only The unused port must be capped by plumber during installation ROUGH IN OF VALVE copper sockets or 1 2 Male I P nipples NOTE UP AND DOWN MARKINGS ON BACK OF VALVE CRITICAL TO PLACE MUD GUARD FLUSH WITH FINISHED WALL FIG 1 3 Anchor installation to bracing between stud...

Page 2: ...HE RING BE SURE THE STEM IS IN THE FULL OFF POSITION maximum hot water temperature FIG 2 FIG 3 HEX CAP TEMPERATURE RING 1 Install extended stem and all thread onto cartridge stem Fully seat stem onto cartridge by tightly securing all thread nipple and locking nut onto valve Install plate and centering nut FIG 4a to extend FIG 4b 3 Place handle on stem and measure excess between escutcheon and hand...

Page 3: ...ose cartridge before setting temperature ring causing a partially opened cartridge Seal on the inlet of the cartridge is faulty Allow approx 3 5 min to drain column Reset the temperature ring as described on Figure 3 Check the seal for cuts or damage and replace if necessary Adjustable handle position stop incor rectly set Reset handle position Check hot water source temperature setting cold water...

Page 4: ...ered ings Corporation s printed instructions In the case of in the wall installations American Faucet and Coatings Corp will as sume no liability if there is no access In no event will we be liable for labor of any kind incidental or consequential damages Many in This does not include Unless otherwise contrary to state law governing the purchase American Faucet and Coatings Corporation s liability...

Reviews: