background image

Sigma

Metalytics

MANUAL - QUICK GUIDE

ERIFIER

Precious Metal

PRO

MODEL #2601

Summary of Contents for PMV Pro 2601

Page 1: ...Sigma Metalytics MANUAL QUICK GUIDE ERIFIER Precious Metal PRO MODEL 2601 ...

Page 2: ......

Page 3: ...reen Basic 7 Interpreting the Measure Screen 8 Measuring Dimensions Weight Mode Weight Select 9 Enter Weight Value 10 Measure Screen with Weight Dimensions 11 Measuring Sample Dimensions 12 Wand Use 13 Thickness Calibration 14 Setup Screen 15 External Bridge Sensor 16 External Bridge Sensor cont 17 Limited Warranty ...

Page 4: ......

Page 5: ...alVerifierPromakenoclaim guaranteeorpromisethatmeasurmentsmade bythePreciousMetalVerifierProindicatesthatanysampleisorisnottheselectedmetaloralloy whetherthereading iswithinorisnotwithintheboundsconsistentwiththeselectedmetaloralloy Toinsureaccuracy readtheinstructions andspecialconditionswhichcanalterthereadingfromoutsidetowithintheexpectedbounds orfromwithintooutside theexpectedbounds Thereading...

Page 6: ...mall Sensor and Bridge Large Sensor and Bridge Sample Placement Circle Active Sensor Lamps ________________________ Dimensions Lamps ________________________ Measurement Scale Sample Placement Circle ________________________ ________________________ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Sample must cover inside of placement circle External Sensor Port Wand Connection Power Connection PMV...

Page 7: ...of the metal Thru Mode In this mode the PMV Pro measures completely through the metal in the sample It measures the characteristic resistance or resistivity completely through the sample Thickness Measurement The PMV Pro electronically measures the thickness of the sample Dimension Verification The PMV Pro allows you to enter the weight of the sample then determine if the overall dimensions are co...

Page 8: ...l Press Silver Silver Pure Wt PM 1 00 Ozt Tot 1 00 Ozt DIM Ready Place Sample Calibration required Remove sample Press Cal button to start Calibrating Please wait Precious Metal Verifier Pro FirmwareVersion 1 01 FPGAVersion 1 03 Database 1 03 Press ...

Page 9: ... bal Cu 90 Bal Cu American Eagle 98 6 Select Gold Silver Pure 92 5 Sterling 90 Coin 1945 96 Britannia Select Silver Platinum Palladium Rhodium Copper Calibrator Select Other Silver Pure 92 5 Sterling 90 Coin 1945 96 Britannia Select Silver When Done Weight Measure Or ...

Page 10: ... Pure 1 59 1 57 Thru Sample Reading Selected Metal Blue charging Green charged Yellow low Red charge immediately Reading inconsistent with selected metal Reading consistent with selected metal Reading cautionary Consistent but possibly affected by relief or contaminants ...

Page 11: ...sensor if possible Silver Silver Pure 1 59 1 57 Silver Silver Pure 1 59 1 57 A red arrow means treat reading with caution Readings will differ significantly Silver Silver Pure Ready Place Sample Silver Silver Pure 1 59 1 57 Verifier Thru readings consistent with selected metal INTERPRETATION GOOD READING Other possible readings below Gold Gold Pure 1 80 1 81 DIM Silver Silver Pure 1 59 2 8 Gold Go...

Page 12: ...ts grams 250 100 50 30 20 10 5 1 Metric Units grams 250 100 50 30 20 10 5 1 Enter Weight English Units Ozt PMWeight 0 000 TotalWeight 0 000 Metric Units grams PMWeight 0 000 TotalWeight 0 000 8 Arrows L R to select Units of PM PM Precious Metal Weights Arrows Up Down to select Value Weight Press Either Enter When Done Measure Or Metal ...

Page 13: ...recious metal or total weight can be entered in oz troy or grams English Units Ozt PMWeight 0001 500 TotalWeight 1 500 Metric Units grams PMWeight 0 000 TotalWeight 0 000 Enter Weight Select Other Enter Weight English Units Ozt PMWeight 1 500 TotalWeight 1 500 Metric Units grams PMWeight 0 000 TotalWeight 0 000 Note weight entered Silver Silver Pure 1 60 1 58 Dia 76 56 mm Thick 6 44 mm Sample Area...

Page 14: ... 1 00 Ozt TotalWeight Ozt or Grams Measure Dimensions Soft Key Diameter round sample mm Sample Area Precious MetalWeight Ozt or Grams Selected Metal DIM Blue when charging Reading inconsistent with selected metal Reading consistent with selected metal Reading cautionary Consistent but possibly affected by relief or contaminants Measure screen weight and size enabled See page 8 to turn on weight an...

Page 15: ...eptable range Measure to Lit Line Place right edge of coin or bar on lit line Area 4591 sq mm MEAS Length Width Lit Line Silver Silver Pure 1 60 1 58 Dia 76 56 mm Thick 6 44 mm Sample Area 4604sq mm Wt PM 10 00 Ozt Tot 10 00 Ozt DIM Instrument must have weight mode on and correct weight entered Arrows Up Down to adjust BarWidth Press When Done Measure 11 ...

Page 16: ...5 2 0 3 5 3 0 4 5 4 0 5 5 1 0 2 5 0 m m 5 5 0 6 5 6 0 7 5 7 0 8 105 110 5 8 0 9 5 9 0 0 1 5 1 1 0 2 1 5 2 1 0 3 1 5 3 1 140 Place sample against dotted lines where indicated Silver Silver Pure 1 61 Plug in wand wand icon will show on screen Calibrate away from metal when using wand Cal Press Refin ers 12 ...

Page 17: ...Calibration Power Cal Metal Measure Weight 10 50 45 40 35 30 25 mm 05 20 15 60 55 80 75 70 65 105 110 100 95 90 85 135 130 125 120 115 140 Place sample against dotted lines where indicated Silver Silver Pure Wt PM 1 00 Ozt Tot 1 00 Ozt DIM Ready Place Sample Place calibration coin under each sensor that that needs to be calibrated 13 ...

Page 18: ...14 SETUP SCREEN Silver Silver Pure 1 59 1 57 Arrows Up Down to select Category Arrows L R to select Condition Press When Done Measure Setup Weight Mode On Off Display Resist Conduct Backlight Low High ...

Page 19: ... weight entry Dimensions Width m7s o Min Length 0 0 Max Length 0 0 Area sq mm 0 0 For bars with angled sides measure in the center of the sides When done press Measure a Reading Results Read measure screen as usual Reading may take several seconds to stabilize Silver Silver Pure 1 60 1 58 Dia 76 56 mm Thick 25 0 mm Sample Area 7585sq mm Wt PM 100 00 Ozt Tot 100 00 Ozt DIM Press Dim ato show length...

Page 20: ...nal Bridge Sensor cont Purpose To verify large bars measuring up to 100 oz 5 kg Bars must be 12 45 mm thick and at least 50 mm wide Attach External Bridge Plug into 15 pin receptor on PRO Attach screws for permanent or long term use Attachment can be done with power on or off Tl 7 Calibration required I I I i5 i i i Calibrate Raise plunger before calibrating Remove s le Press Cal E Button Wait for...

Page 21: ...r original sales receipt from your purchase to receive our warranty service This limited hardware warranty does not cover problems that result from External causes such as accident abuse misuse or problems with electrical power Servicing not authorized by Sigma Metalytics Usage that is not in accordance with product instructions Failure to follow the product instructions Problems caused by using a...

Page 22: ...ERIFIER Precious Metal PRO Sigma Metalytics www sigmametalytics com Made in USA US Patent No 9 922 487 Pending MODEL 2601 email info sigmametalytics com TM TM PM TM V ...