84 SSG5000A Programming Guide
Parameter Type
Integer, Integer
Parameter Range
Raw: 1 ~ count of pair.
Count: 1 ~ 65535
Return
None
Default
None
Menu
PULSE > Pulse Train
Example
:PULM:TRAin:DATA:COUNt
1,3
3.5.8.18 Pulse Train Edit ([:SOURce]:PULM:TRAin:CHANGe)
Command Format
[:SOURce]:PULM:TRAin:CHANGe
<row>,<on_time>,<off_time>,<count>
Instruction
Edit train pair value
Parameter Type
raw: integer,
on_time: float, unit: ns, us, ms, s, and default is s,
off_time: float, unit: ns, us, ms, s, and default is s,
count: integer.
Parameter Range
raw: 1 ~ count of pair,
on_time: 20ns ~ 300s,
off_time: 20ns ~ 300s,
count: 1 ~ 65535.
Return
None
Default
None
Menu
PULSE > Pulse Train
Example
:PULM:TRAin:CHANGe
2,3 ms,500 ns,4
3.5.8.19 List Pulse Train ([:SOURce]:PULM:TRAin:LIST?)
Command Format
[:SOURce]:PULM:TRAin:LIST? <begin_row>,<end_row>
Instruction
View starting row to end row data
Parameter Type
Integer, Integer