background image

 
 

 

Summary of Contents for MH-M80

Page 1: ......

Page 2: ...0 Manufacturer Information Sigineer Power Limited Email info sigineer com TEL 86 769 82817616 US Warehouse 4415 S 32nd St Phoenix AZ 85040 ...

Page 3: ...NS 5 1 3 SPECIFICATIONS AND PARAMETERS 5 1 4 PACKING LIST 6 1 5 PRODUCT FEATURES 7 2 INSTALLATION INSTRUCTIONS 9 2 1 INSTALLATION METHOD 9 2 2 INSTALLATION STEPS OF ACCESSORY HANGING PLATE 10 3 OPERATING INSTRUCTIONS 13 3 1 HOME PAGE AND REAL TIME DATA PAGE 13 3 2 MAIN MENU PAGE 15 ...

Page 4: ...er setting 18 3 3 4 Time synchronization setting 18 3 3 5 Reset MPPT controller 19 3 3 6 Load output mode setting 20 3 4 TREND CHART FUNCTION PAGE 22 3 4 1 Today charging power trend 23 3 4 2 Daily power generation trend 24 3 4 3 Monthly power generation trend 25 4 STATUS INDICATION 26 5 WARRANTY 27 6 APPENDIX 28 ...

Page 5: ...e goods are damaged during transportation If you find any problems please contact our company or transportation company Please read the instructions and precautions in the manual before installation to ensure that the product can work normally Do not place this product in the environment of rain exposure corrosion and strong electromagnetic interference Avoid water entering the product Do not open...

Page 6: ...tify and display relevant parameters of connected equipment OLED real time display of operation data and working status Six navigation function keys for intuitive convenient and fast operation Directly supply power to the display unit through the controller without additional external power supply Support real time data monitoring remote load switch data browsing and modification of equipment para...

Page 7: ...ing status of a single on line controller presentation of columnar trend chart of power generation data browsing and modification of charge and discharge control parameters setting of equipment parameters load control parameters time correction and restoration of factory default parameters 1 3 Specifications and parameters Mechanical Value Dimension 80mm diameter 17 5mm high Mounting hole 3mm ...

Page 8: ...mption 0 5W Power supply Connect to controller Communication RS485 bus please do not install this equipment in an environment with strong electromagnetic interference 1 4 Packing list Monitoring display unit 1 pcs M3 stainless steel countersunk head screw 3 pcs Install the backplane 1 pcs M3 countersunk head tapping screw 3 pcs ...

Page 9: ...7 Instructions 1 pcs Expanded colloidal particles 3 pcs 1 5 Product features 1 indicator light 2 display window ...

Page 10: ...8 3 Operation buttons 4 Connecting cable 5 Metal hanging plate limit detent 6 Metal hanging plate mounting hole 7 Metal hanging plate assembly 8 Magnet buckle 9 Limit slot ...

Page 11: ...Application 1 when the MPPT controller is an iron shell or installed on an iron plate mh m80 can be directly adsorbed on the controller shell or iron plate through the magnet buckle on the back Application 2 when the installation position cannot be magnetically absorbed it can be installed and fixed through the iron installation hanging plate of the accessories ...

Page 12: ...ep 1 place the hanging plate assembly at the position to be installed mark the hole position on the installation wall drill 3 holes positions at the marked position and fill the plastic expansion rubber sleeve or make 3 M3 screw holes at the marked position ...

Page 13: ...hole position made in step 1 with counter sunk 3mm self tapping screw or M3 screw Step 3 align the limit slot hole on the back of the monitoring unit with the limit snap pin of the hanging plate to make the monitoring unit adsorb on the hanging plate ...

Page 14: ... 4 connect the RJ45 plug of the connecting cable of the monitoring unit to the RJ45 communication port of the controller When the display screen is normally on it indicates that the installation is successful ...

Page 15: ...r address is consistent with the monitoring unit In order to synchronize the data of the monitoring unit with the controller please set the time and date of the monitoring unit 3 1 Home page and real time data page As shown on the left of the figure below the main dynamic data output is displayed on the home page You can browse other pages in the figure through the key Press ENT on these pages to ...

Page 16: ...14 ...

Page 17: ...press ESC key to return to the previous page 3 3 Page for setting functions After entering the parameter setting interface the options of address setting charging parameter setting protection parameter setting time synchronization setting MPPT controller reset setting and load output mode setting will appear You can select the required function items by pressing press ENT to enter the selected set...

Page 18: ...ontroller only one MPPT controller can be accessed when using this function and the same device address will be set if multiple MPPT controllers are connected change the value by key move the cursor position by press ENT key to save the set parameters and press ESC key to return to the previous page ...

Page 19: ...ress ENT to save the set parameters and press ESC to return to the previous page When the battery type is GEL FLD and SEL the charging parameters are solidified values and cannot be modified The lead acid battery is set according to the conversion setting of each 12V battery and the lithium battery is set according to the actual voltage value of the battery pack ...

Page 20: ...rs the user can set the protection parameters change the value by key move the cursor by press ENT key to save the setting parameters and press ESC key to return to the previous page 3 3 4 Time synchronization setting Before the MPPT controller works be sure to set the time ...

Page 21: ...ze the controller data press ENT to execute the reset action and press ESC to return to the previous page When the operation is successful the power generation consumption information of the controller the operation parameter information of the controller the protection parameter setting of the controller the charging parameter setting of the controller and the load application setting of the cont...

Page 22: ...ad output mode setting As shown in the figure below when the cursor is in the load mode position you can select different modes by pressing move the cursor by pressing and press ESC to return to the previous page ...

Page 23: ...ol modes and different setting content pages will appear Change the required value by key move the cursor by press ENT key to save the setting and press ESC key to return to the previous page Light control mode Off mode On mode ...

Page 24: ...control mode Fixed time light control mode 3 4 Trend chart function page As shown in the figure below the data items of today s charging power daily power generation and monthly power generation will appear on ...

Page 25: ...ressing ESC 3 4 1 Today charging power trend As shown in the figure below press ENT to enter the graphical interface The monitoring instrument will record the generation power track from 6 00 a m to 19 00 p m every day the left of the figure starts at 6 00 and the right ends at 19 00 p m and the data will be cleared at 24 00 p m every day The maximum power value is ...

Page 26: ...d As shown in the figure below press ENT to enter the graphical interface and the monitoring instrument will obtain the daily power generation data of the last 31 days from the controller for display The first on the right is today s data the first on the left is the data of 30 days ago and the top shows the maximum power generation value of the last 31 days ...

Page 27: ...nd the monitoring instrument will obtain the monthly power generation data of the last 12 months from the controller for display The first on the right is the data of this month the first on the left is the data before 11 months and the top displays the monthly maximum power generation value of the last 12 months ...

Page 28: ...it is off it indicates off mode Blue It indicates the charging state when it flashes quickly it indicates the fast charging state CC when it flashes slowly it indicates the constant voltage charging state CV when it is always on it indicates that it is in floating charge state CF or standby mode Red It will flash when there is a fault but it can still run It will always be on when the fault causes...

Page 29: ...nd provide the bill information related to the purchase as the warranty basis In order to enjoy the quick repair guarantee service the returned products need to be marked with model number operating environment data and detailed description of faults This information is important to address your service requirements If the equipment is damaged due to improper use or failure to follow the operation...

Page 30: ...28 6 APPENDIX RJ45 interface pin definition Pin Function 1 RS485 A 2 RS485 B 3 Dry Contact 4 Dry Contact 5 GND isolation 6 GND isolation 7 5V isolation 8 5V isolation ...

Page 31: ...29 ...

Page 32: ...30 ...

Reviews: