![Sigfox SMK Access Station Mini Installation Manual Download Page 7](http://html1.mh-extra.com/html/sigfox/smk-access-station-mini/smk-access-station-mini_installation-manual_1267322007.webp)
7
2.3 Systems proximity
In case of third party equipment in close proximity, with line of sight visibility and
horizontal alignment, following physical separation is recommended:
System type
Minimum physical
separation
100KW Broadcast (FM or digital TV DBV-T)
1000 m
cellular macrocell (N x 2kW panel)
50 m
868-925 MHz SRD / ISM equipment
200 m
Wi-Fi
2 m
2.4 Admissible energy
SMK access station mini shall not be exposed to signals greater than -20dBm
from 0 to 821MHz and from 925MHz to 2.5GHz.
SMK access station mini shall not be exposed to integrated power greater than
1mW /- 200 MHz from its operating frequency.
Regardless the type of installation, the base station must be installed away from
obstacles possible altering the reception, and so that its RF connector must not
receive more than -20dBm signals from 0 to 821MHz and from 925MHz to
2.5GHz.
3 WARNING STATEMENTS and KEY RISK
See Product Manual