Sierra SRHP-2-12 Owner'S Manual Download Page 3

3 to 10 

All equipment manufactured by SIERRA CORP. is for use with the type of gas specified on the rating plate and 
for installation will be in accordance with National Fuel Gas Code ANSI Z223.1 (latest edition) 

IMPORTANT: Installing, Operating and Service Personnel: 

Qualified, certified licensed and/ or authorized personnel who are familiar with and experience in state/local 
installation codes should perform installation of the equipment. Qualified or authorized personnel who have 
read  this  manual  and  are  familiar  with  the  functions  of  the  equipment  should  perform  operation  of  the 
equipment. 

Qualified personnel who are knowledgeable with Sierra equipment should perform service of the equipment. 

The BTU input rating on all equipment is calibrated for elevations up to 2,000 feet above sea level. All orifice 
drill sizes are referenced for operation at or below this altitude. For operation at elevations above 2,000 feet, 
the BTU rating must be reduced 4% for each 1,000 feet of elevation or the orifice drill size must be changed 
appropriately. For high altitude drill sizes, call your local gas company or Factory Authorized Service Center. 

All units are equipped with fixed orifices and cannot be adjusted. If converting the gas appliance from natural 
to propane, or vice versa, all orifices and the regulator must be changed. The correct type of gas, for which the 
unit is configured, is noted on the name plate. The type of gas specified MUST be used. For proper conversion, 
contact a qualified service technician or your Factory Authorized Service Center. 

SHIPPING DAMAGE CLAIM PROCEDURE 

Merchandise must be inspected prior to the carrier leaving your premises. Damage must be noted in writing 
on the BOL and pictures must be taken at this time.  

- For any goods shipped prepaid by MVP Group Corp., and the goods are damaged and/or lost in transit, please
call the Logistics Department at MVP immediately (1-888-275-4538 x 333)

- MVP Group will not be held responsible for damages that are not notated on the BOL or not reported within
5 business days of being delivered.

- For goods shipped via 3rd party carrier, any claim for damages or loss must be made by the consignee
directly with the carrier. MVP Group Corp. assumes no responsibility for damage or loss while in transit.

INSTALLATION INSTRUCTIONS 

Gas pressure regulator provided with the equipment must be installed when the appliance is connected to gas 
supply. The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning 
liquid,  broom,  rags, etc.  Proper  clearances must  be  provided  at  the  front  of  the  appliance  for  servicing  and 
proper operation. 

Summary of Contents for SRHP-2-12

Page 1: ...2 SRHP 4 24 SRHP 6 36 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 12000 BISCAYNE BLVD STE 108 MIAMI FL...

Page 2: ...on adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this eq...

Page 3: ...nverting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate The...

Page 4: ...d to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached...

Page 5: ...n and brush off debris from and around the burner area Empty and clean grease pan Griddle plates should be cleaned with warm water and scrubbed with cleaning abrasive such as a griddle brick of fine g...

Page 6: ...s than under any circumstances All connections must be tested with a soapy water solution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attem...

Page 7: ...pliance area must be kept free and clear of all combustibles SR SRMR Series products are for installation in Non Combustible locations only COMBUSTIBLE NON COMBUSTIBLE SIDES 12 Inches 0 Inches REAR 8...

Page 8: ...RECT GAS GAS SUPPLY PRESURE CONTACT LOCAL GAS SUPPLIER PRIMARY AIR NOT ADJUSTED PROPERLY ADJUST AIR SHUTTER ORIFICE TOO BIG VERIFY ORIFICE SIZE PILOT WILL NOT REMAIN LIT PILOT FLAME NOT ADJUSTED ADJUS...

Page 9: ...erra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any c...

Page 10: ...514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canad H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United State...

Reviews: