Sierra SRHP-2-12 Owner'S Manual Download Page 1

OWNER´S MANUAL 

INSTRUCTIONS- INSTALLATION-OPERATION-MAINTENANCE 

HOT PLATES 

SRHP-2-12, SRHP-4-24, SRHP-6-36 

**READ THIS MANUAL IN IT’S ENTIRELY BEFORE USING THIS

 EQUIPMENT** 

5659 ROYALMOUNT AVE

.

MONTREAL, QC, CANADA H4P 2P9 
TEL (514) 737-9701; 1-888-275-4538 

12000 BISCAYNE BLVD. STE 108

MIAMI, FL 33181

TEL (786) 600-4687; 1-844-218-8477

[email protected]         www.mvpgroupcorp.com

Summary of Contents for SRHP-2-12

Page 1: ...2 SRHP 4 24 SRHP 6 36 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 12000 BISCAYNE BLVD STE 108 MIAMI FL...

Page 2: ...on adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this eq...

Page 3: ...nverting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate The...

Page 4: ...d to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached...

Page 5: ...n and brush off debris from and around the burner area Empty and clean grease pan Griddle plates should be cleaned with warm water and scrubbed with cleaning abrasive such as a griddle brick of fine g...

Page 6: ...s than under any circumstances All connections must be tested with a soapy water solution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attem...

Page 7: ...pliance area must be kept free and clear of all combustibles SR SRMR Series products are for installation in Non Combustible locations only COMBUSTIBLE NON COMBUSTIBLE SIDES 12 Inches 0 Inches REAR 8...

Page 8: ...RECT GAS GAS SUPPLY PRESURE CONTACT LOCAL GAS SUPPLIER PRIMARY AIR NOT ADJUSTED PROPERLY ADJUST AIR SHUTTER ORIFICE TOO BIG VERIFY ORIFICE SIZE PILOT WILL NOT REMAIN LIT PILOT FLAME NOT ADJUSTED ADJUS...

Page 9: ...erra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any c...

Page 10: ...514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canad H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United State...

Reviews: