OWNER´S MANUAL 

INSTRUCTIONS- INSTALLATION-OPERATION-MAINTENANCE 

 

RADIANT BROILER 

 

SRRB-12, SRRB-24, SRRB-36, SRRB-48, SRCB-24, SRCB-36 , SRCB-48 

 

**READ THIS MANUAL IN IT’S ENTIRELY BEFORE USING THIS 

EQUIPMENT** 

 

 

 

 

 

 

 

 

 

 

 

5659 ROYALMOUNT AVE MONTREAL, QC, CANADA H4P 2P9 
TEL (514) 737-9701; 1-888-275-4538 

Summary of Contents for SRCB-24

Page 1: ...ION OPERATION MAINTENANCE RADIANT BROILER SRRB 12 SRRB 24 SRRB 36 SRRB 48 SRCB 24 SRCB 36 SRCB 48 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 ...

Page 2: ...ation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lisez sougneusement les in...

Page 3: ...onverting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Merchandise must be inspected...

Page 4: ...ent of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached to the back frame panel of the unit All Sierra appliances are adjusted and tested before leaving the factory effectively matching them to sea level conditions Adjustments and calibrations to assure proper operation may ...

Page 5: ...h hot soapy water then reassemble Baked on spills may be loosened and stubborn stains removed with ordinary household ammonia and scrubbing with a nylon pad in a cold oven only Do not allow spray type oven cleaners to come into contact with the temperature probe in the oven After cleaning the oven rinse well with 1 4 cup of vinegar to one quart of clear water solution to neutralize any caustic res...

Page 6: ...ny circumstances All connections must be tested with a soapy water solution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the installation instructions the serving gas supplier or the appliance manufactu...

Page 7: ...ea must be kept free and clear of all combustibles SR SRMR Series products are for installation in Non Combustible locations only COMBUSTIBLE NON COMBUSTIBLE SIDES 12 Inches 0 Inches REAR 8 Inches 0 Inches FLOOR 6 Inches 0 Inches AIR SUPPLY VENTILATION The area in front of around and above the appliance must be kept clear to avoid any obstruction of the flow of combustion and ventilation air Adequ...

Page 8: ...GAS GAS SUPPLY PRESURE CONTACT LOCAL GAS SUPPLIER PRIMARY AIR NOT ADJUSTED PROPERLY ADJUST AIR SHUTTER ORIFICE TOO BIG VERIFY ORIFICE SIZE PILOT WILL NOT REMAIN LIT PILOT FLAME NOT ADJUSTED ADJUST PILOT FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVER...

Page 9: ...ierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional ...

Page 10: ...0 514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canadá H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...