Differences between GM47 and GM47r5
LZT 123 7733 R1A
10
4 Software
Differences
4.1 AT
Commands
4.1.1 AT*E2IO
Changed designators:
With the exception of the four items listed below the GM47r5/GM48r5 will
operate successfully in any application designed for the GM47/GM48.
PIN
GM47 Signal
GM47r5 Signal
32 O5 O3
36 O6 O2
37 I5 I1
38 O7 01
Addressing these inputs and outputs with the designations referred to for
GM47 using the AT*E2IO command will return error when used on
GM47r5.
The GM47r5 will accept an extra parameter, 6, allowing pins to switch
functionality as required.
Note:
Pin 37 - GM47 ‘5’and GM47r5 ‘I1’ is now not a triggerable input.
The trigger functionality on this pin is lost in GM47r5. However - the
GM47r5 AT*E2IO command now supports the extra IO, ‘IO5’, which is
triggerable, and has the same functionality as ‘IO1’ to ‘IO4’.
4.1.2 AT*E2RS232
This is a new command recognised by the GR modules, not the GM.
When ‘Full RS232’ is selected (Factory default) all IO commands on these
pins will return ‘error’.
E.G. AT*E2IO commands on ‘I1’, ‘O1’, ‘O2’ and ‘O3’ will return error
unless AT*E2RS232 status is modified to allow operation on these pins.