GL61x0 Product Technical
Specification and User Guide
GL61x0 Feature Set
2.1.
Supported Bands
The GL61x0 supports either EU bands (EGSM900/DCS1800) or US bands (GSM850/PCS1900).
Users may switch from one supported band to another using AT commands.
Refer to sections 8.4 Checking the Band Selection and 8.5 Switching Bands for more information
regarding switching bands.
2.2.
Protection
2.2.1.
Power Supply
2.2.1.1.
GL6100
– UART Version
The GL6100 is protected against voltage over +32V. When the input voltage (Vin) exceeds the limit,
the supply voltage is disconnected to protect the internal electronic components from overvoltage.
Note:
An 800mA/250V fuse is directly bonded on the Adaptive cable of GL6100. The fuse model is
FSD
800mA/250V FAST-ACTING
.
Figure 2. Adaptive Cable Fuse
2.2.1.2.
GL6110
– USB Version
The GL6110 is protected against voltage over +5V. When the input voltage (Vin) exceeds the limit,
the supply voltage is disconnected to protect the internal electronic components from overvoltage.
2.2.2.
Electrostatic Discharge
The GL61x0 withstands ESD according to IEC 1000-4-2 requirements for all accessible parts, except
for the RF connector which withstands ESD as follows:
+/- 8kV of air discharge
+/- 4kV of contact discharge