Sierra Wireless AirLink Raven XE Manual Download Page 3

 

Page 

3

 of 

4

 

 

4)

 

You will be entering the IP address of 192.168.13.31 with the default username and the 
appropriate password.   

5)

 

Follow the instructions given by the upgrade program. 

 

The Raven XE’s manual also covers how to upgrade the firmware easily. 
  

Upload Inductive Automation Template 

You will now upload the Raven XE to use Inductive Automation’s Template: 

1)

 

From the ACEManager, press the Upload link. 

2)

 

Select the file on your computer called 

IA_SWTemplate_02252013.xml

3)

 

Press the Load & Apply button. 

4)

 

You will then be asked to reboot the Raven; do so.  The entire procedure takes 
about 3-4 minutes.  You will then be able to re-access the ACEManager at 

http://192.168.13.31:9191/index.htm

 

Finalizing the Raven XE for your Network 

At this point you should change the Raven XE IP configuration to be appropriate to your 
network.  Additionally, you should now review the security settings of the Raven XE to see if 
there are additional settings you need to account for.  See the Security tab under the 
ACEManager.  Again, it is not Inductive Automation’s responsibility to secure the Raven XE from 
unwanted inbound and outbound traffic. 
 
Remember, any change you make on the Raven XE will require a reboot.  You should now be 
ready to plug it into your network.  
 

Testing SMS 

Now that your Raven XE is on the network, let us see if you can send and receive SMS messages.  
If you haven’t already, install you SIM card into the Raven XE. 
 
If you have loaded the Inductive Automation template you will connect via an SSH client such as 

Putty

.  The user name and password will be the same that is used to connect to the 

ACEManager. 
 
The following are basic commands to send an SMS message: 
 

at*smsm2m="1XXXXXXXXXX This is SMS test message." 

 
To send a test message to itself: 

at*phonehome=1XXXXXXXXXX 

 

1XXXXXXXXXX is the number for the Raven XE. 

 