IMPORTANT INSTRUCTIONS 

Read all instructions before installing or using this heater. 

 

2.  Keep  combustible  materials,  such  as  furniture,  pillows,  bedding,  papers,  clothes  and 

curtains at least 3 feet from the front of the heater; keep them away from sides and rear 

as well.   

3.  Always unplug heater when it

s not in use.   

4.  Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or 

if the unit has been dropped or damaged in any way. 

5.  This  heater  is  not  intended  for  use  in  bathrooms,  laundry  areas  and  similar  indoor 

locations.  Never  place  the  heater  where  it  may  fall  into  a  bathtub  or  other  water 

containers.   

6.  Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners or 

anything else. Arrange the cord away from traffic areas where it could not be tripped over.   

7.  To disconnect the heater, turn the controls to "OFF" before removing the plug from the 

outlet.   

8.  Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this 

may cause an electric shock, fire or damage to the heater.   

9 . To prevent a possible fire, do not block air intakes in any manner.   

10. A  heater  has  hot  and  arcing  or  sparking  parts  inside.  Do  not  use  it  in  areas  where 

gasoline, paint or flammable liquids are used or stored.   

11. Use this heater only as described in this manual. Any other use not recommended by the 

manufacturer may cause fire, electric shock or injury to persons.   

12. Avoid the use of an extension cord because the extension cord may overheat and cause 

a fire. 

13. Always use properly grounded fused and polarized outlets. 

14. Always use ground fault protection where it is required by electrical codes. 

15. Always disconnect the power before performing any cleaning, maintenance or relocation 

of the heater. 

16. To prevent a possible fire, do not burn wood or other materials in this heater. 

17. To prevent electric shock or fire, always use a certified electrician, should new circuits 

or outlets be required. 

When transporting or storing the heater, keep it in a dry place, free from excessive 

vibration.

 

1. 

18. 

Summary of Contents for VISTA-BI-50-7

Page 1: ...ion in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE ...

Page 2: ...t you have many years of dependable and enjoyable service from your Amantii product IMPORTANT INSTRUCTIONS 3 UNPACKING AND TESTING APPLIANCE 4 GROUNDING APPLIANCE 4 LOCATING THE FIREPLACE 4 VISTA BI 50 7 5 VISTA BI 60 7 6 VISTA BI 72 7 7 INSTALLATION 8 HARD WIRE INSTALLATION 9 Media Options 10 OPERATION 11 INSTALLING WALL THERMOSTAT 13 REPLACEMENT PARTS 14 EXPLODED VIEW 15 TROUBLE SHOOTING 16 SERV...

Page 3: ...allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock fire or damage to the heater 9 To prevent a possible fire do not block air intakes in any manner 10 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored 11 Use this heater only as described in this manual Any other...

Page 4: ...y grounded outlet box The adapter should not be used if a three slot grounded receptacle is available To disconnect appliance turn controls to off then remove plug from outlet LOCATING THE FIREPLACE Plan where to locate and frame the fireplace This will save time and money later when you install the fireplace Before installation consider the following 1 Where the fireplace is located must allow fo...

Page 5: ...ning Size 50 24 or 127 cm 60 cm This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes us the cur...

Page 6: ...ing Size 60 24 or 152 4 cm 60 cm This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes us the cu...

Page 7: ...g Size 73 1 2 24 or 186 7 cm 60 cm This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes us the ...

Page 8: ...t directly from the unit It will need two person to do it The rough wall opening size of the fireplace W D H VISTA BI 50 7 50 7 1 2 24 VISTA BI 60 7 60 7 1 2 24 VISTA BI 72 7 73 1 2 7 1 2 24 1 Take out the unit from the box Do the pre test before you install the fireplace Pull out the optional trim from the unit as show 2 Screw the framing plates to the fireplace 3 Bent up the framing plates 4 Ins...

Page 9: ...ouse hold wiring This appliance must be electrically connected and grounded in accordance with local codes if hard wired In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States 1 Remove the cover plate from the left side of the appliance by removing the two screws as shown below Unscrew and...

Page 10: ...hold the front glass It is show as below Unscrew the screw and take off the bracket Turn around and insert to the gap It can hook the glass and pull out the glass 2 Installing the fire media Pour the fire media into the tray as shown below Feel free to use any combination of fire media that you find most appealing 3 Put back the front glass and screw back the bracket ...

Page 11: ...When the room temperature goes above 25 the heater will be turned off and the cycle will continue The LED indicator will be PURPLE in colour under this mode 4 Flame effect Press the button marked Flame to adjust the flame brightness The flame brightness will cycle through Low Medium High OFF NOTE If operated at the Low heat setting the fireplace will not provide as much heat output as in the High ...

Page 12: ... will turn off all the functions and the fireplace will be in standby mode DISPLAY ON OFF button Switching the fireplace flame and tray light ON OFF It has functions of setting memory BLUE button Adjust the blue color brightness of flame and tray YELLOW button Adjust the yellow color brightness of flame and tray ORANGE button Adjust the orange color brightness of flame and tray HEATER ON OFF butto...

Page 13: ...G 24 VAC Install Wall Thermostat per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Pull the wire out and cut the inside thermostat Connect the wires to the wall thermostat as shown below Follow instructions provided with wall switch kit ...

Page 14: ... MOTOR 1 7 3057503 3110503 3058503 FLICKER ASSEMBLY 1 8 601136B 601136B 601137B LED STRIP 9 10203015 10203015 10203015 ADJUSTABLE FOOT 4 10 FLAME EFFECT GLASS CLEAR GLASS WITH BLACK PLASTIC 1 11 3057012 3057012 3057012 GLASS BRACKET LH 1 12 3057013 3057013 3057013 GLASS BRACKET RH 1 13 10702156 BOTTOM GLASS 1 14 357017 3110017 358017 MEDIA HOLD BRACKET 2 15 3057016 3057016 3057016 FRONT GLASS BRAC...

Page 15: ...15 EXPLODED VIEW ...

Page 16: ... plugged into an electrical outlet Check plug and plug in Appliance has overheated and safety device has caused the thermal switch to disconnect Turn off the main switch allow appliance to cool for 10 minutes then turn it on Appliance will not come on when switch is flipped to ON Circuit board is burnt out Inspect the circuit board and replace it if necessary No warm air coming out of appliance He...

Page 17: ...17 SERVICE HISTORY This heater must be serviced annually depending on usage Date Dealer Name Service technician Name Service Performed Special Concerns NOTES ...

Page 18: ...e your proof of purchase catalogue model and serial numbers available when calling any and all service under the limited warranty requires a proof of purchase of the product Defects Should a product or part covered by this limited warranty be proven to be defective in material or workmanship and during the one 1 year limited warranty period Sierra Flame will replace such defective product or part ...