8 – 1
8
Schaltpläne
8.1
Klemmenbelegung
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Fern-Rücksetzmagnet
/
Remote reset bell alarm & tripped indicator F7
CUB +
CUB -
24 V d.c.
0 V d.c.
G-Wandler
/
Ground Fault Sensor S1
G-Wandler
/
Ground Fault Sensor S2
N-Wandler
/
Neutral Sensor S1
N-Wandler
/
Neutral Sensor S2
Externer Spannungswandler
/
External voltage transformer
L1
Externer Spannungswandler
/
External voltage transformer
L2
Externer Spannungswandler
/
voltage
External
transformer
L3
Externer Spannungswandler Stern
/
External voltage transformer Com
COM15/16, sonst nicht belegt
COM15/16, otherwise empty
1
2
3
4
5
6
7
8
9
10
11
12
13
14
S 2
S 2
Einschaltbereitschaftsmeldung
/
“Ready to close” signal
S20
Einschaltmagnet
/
Closing Coil CC
S1
S1
1st Shunt Trip.
X8
X7
X6
X5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Charging motor (optional motor
cut-off switch shown in figure).
S 4
S 4
S 3
S 3
zweiter Hilfsauslöser: F3 “
", F4 “
"
UVR
UVR td
2nd
:
auxiliary release F3 "UVR", F4 "UVR td"
nur F4 "Schnell-AUS"
/
F4 only “quick OPEN”
0053-07_n
u
Intern
Internal
Extern
External
Klemmen
Terminals
ANSI
C37.2
device
#
LT / (+)
Control power
N / (-)
NOT-AUS oder Brücke
EMERGENCY OPEN
or short terminals
Phase A
Phase B
Phase C
24 V d.c. input
Abschlusswiderstand, 120
, 0.5 W
wenn kein externes CubicleBUS-Modul
O
Termination resistor
if no
external CubicleBUS module connected
, 120
, 0.5 W
O
Brücke, wenn kein N-Wandler
Short terminals, if no Neutral sensor
1
2
3
4
5
6
7
8
9
10
11
12
13
14
30
52CS
52CC
52CS
52TC
79
52TC / 86
52a
52b
52b
52b
52a
52a
52LC
52CC
52a
52b
52M
62
27
Meldeschalter am zweiten Hilfsauslöser
Signalling switch for 2nd shunt trip
Elektrisch "EIN"
/
Local electric close
S10
Meldeschalter am ersten Hilfsauslöser
Signalling switch for 1st shunt trip
Ausgelöst-Meldeschalter
/
Bell alarm signal switch
S24
Meldeschalter Fernauslösung
/
Signalling switch remote trip
S26
Maglatch for remote trip kit F6
2. Hilfsauslöser
/
2nd shunt trip
F2
X9
LT / (+)
Control power
N / (-)
LT / (+)
Control power
N / (-)
LT / (+)
Control power
N / (-)
LT / (+)
LT / (+)
Control power
Control power
Fuse carriage FS III
N / (-)
X9.3
X9.4
LT / (+)
Control power
N / (-)
cc
OFLO
BA
TC
TC
CC
b
a
a
a
b
a
b
M
b
8
Circuit diagrams
8.1
Terminal assignment
Summary of Contents for WL Series
Page 64: ...7 2 Horizontalanschlüsse 0733_nu top view Horizontal connectors ...
Page 65: ...7 3 Vertikalanschlüsse 0734_nu top view rear view Rear vertical connectors ...
Page 66: ...7 4 Frontanschlüsse 0736_nu front view top view Front connectors ...
Page 68: ...7 6 7 2 Baugröße II Festeinbau 0494 3_nu 7 2 Frame size II fixed mounted version ...
Page 69: ...7 7 C class always 0494 5_nu top view rear view ...
Page 70: ...7 8 0738_nu LH side view front view ...
Page 72: ...7 10 0495 2_nu top view top view ...
Page 73: ...7 11 0495 3_nu top view rear view ...
Page 74: ...7 12 0739_nu LH side view front view ...
Page 76: ...7 14 Baugröße II III 0496_nu Frame size II III ...
Page 77: ...7 15 7 5 Baugröße I Einschubausführung 0745_nu 7 5 Frame size I draw out version ...
Page 78: ...7 16 0746_nu rear view top view ...
Page 79: ...7 17 0747_nu bottom view ...
Page 80: ...7 18 0748_nu ...
Page 81: ...7 19 0749_nu ...
Page 82: ...7 20 7 6 Baugröße II Einschubausführung 0490 1_ul 7 6 Frame size II draw out version ...
Page 86: ...7 24 7 7 Baugröße III Einschubausführung 7 7 Frame size III draw out version ...
Page 87: ...7 25 ...
Page 88: ...7 26 ...
Page 111: ...9 11 I Auslösung Erdschlussauslösung I tripping Ground fault tripping ...
Page 360: ......
Page 361: ......