![Siemens WEBUI Quick Manual Download Page 60](http://html.mh-extra.com/html/siemens/webui/webui_quick-manual_382823060.webp)
SOFTWARE UPDATES
6-4
SIG-QG-20-02
JANUARY 2021
Version : A.2
continue. The configuration will now be updated in the CPU and the CPU will reboot, this will cause the
display to temporarily lose the session with the CPU.
If the upload is cancelled at the stage above, and the user wants to put the CPU back into an operational
state, the VLP will need to be rebooted as described previously.
Figure 6-6 WebUI: Configuration Upload Progress and Final Check
6.1.2 Vital CPU/Module
NOTE
In order to load new software into a CPU II+ (A80403), track module
(A80418) or RIO module (A80413) a serial cable with null modem needs to
be connected between the serial port on the front of the display and the
DIAG port on the module whose software is to be updated.
NOTE
In order to load new software into a track module (A80418) or RIO module
(A80413) from the CPU III, a serial cable with null modem needs to be
connected between the serial port on the front of the CPU III and the DIAG
port on the module whose software is to be updated. To update software on
the CPU III itself, an Ethernet cable can be plugged directly into the module
itself and the WebUI used, or if the unit is on the network, the IP address of
the CPU III can be used to login remotely.
To update the software on the CPU II+, Track or RIO module, select the Vital CPU / Module option.
Summary of Contents for WEBUI
Page 30: ...SYSTEM VIEW 2 14 SIG QG 20 02 JANUARY 2021 Version A 2 This page intentionally left blank ...
Page 40: ...CONFIGURATION 3 10 SIG QG 20 02 JANUARY 2021 Version A 2 This page intentionally left blank ...
Page 72: ...CPU III WEBUI 8 2 SIG QG 20 02 JANUARY 2021 Version A 2 This page intentionally left blank ...