1. Ensure that all cables are pulled and labelled correctly.
Note:
ensure the cables are cut with enough length
(approx. 1 meter) to allow termination to the User Unit.
2. Ensure that conduits are cut to 70mm from the
foundation ground.
3. Cut the M16 mounting rods down to 50mm from the
foundation
ground.
Note:
Do not use less than M12.
4. Clean the foundation of any debris.
5. Inspect the mounting rods to ensure they are straight,
and the threads are clean.
Figure 15: Completed User Unit Foundation Preparation
4.7.2 Unboxing and craning
1. Remove the lid and walls from the shipping box.
Note:
For more information, see VersiCharge 175 kW Fast
Charger User Unit Installation Manual.
Figure 16: User unit lifting points (indicative)
2. Attach lifting straps to the crane.
3. Slowly lift the user unit until clear of the ground.
4. Lower the unit to the ground in a vertical position, using
the crane to keep tension.
5. Remove the protective plastic wrapping from the lower
portion of the user unit.
6. Remove the screws that hold the front lower panel.
7. Remove the front, lower panel and store in a safe
location to prevent damaged or scratching.
8. Remove the timber base plate.
9. Use the crane to lift the User Unit in place over the
foundation.
10. Feed the cables through the hole in the foundation plate.
11. Align the rods from the foundation through the
mounting holes in the base, and then lower into place.
12. Ensure that the plastic grommets are inserted into the
foundation plate.
13. Apply anti-seize compound to the mounting rods.
14. Use M16 nuts and flat washers to fasten the User Unit to
the foundation, then torque to 40Nm (or 30Nm for M12).
15. Stow cables beneath the User Unit for protection until
ready for cable termination (see Figure 17).
Figure 17: Mounted User Unit, and User Unit Cable Storage
(Images indicative only)
WARNING!
Be aware that lifting heavy loads that are inadequately
secured could damage the product and cause serious
injury.
Be careful as the unit may shift. A second operator may be
required to control the user unit lift.
VersiCharge Ultra 175™ kW Fast Charger |
Site Installation Manual