WARNING

Explosion due to fire or short circuit, even with discharged batteries

Risk of injury due to flying parts

  Prevent the batteries from coming into contact with water.

  Do not recharge batteries.

  Do not damage or disassemble batteries.

  Do not expose batteries to temperatures over 85 °C.

WARNING

Leakage of electrolyte

Severe burns

  Handle damaged batteries only wearing suitable protective gloves.

  In case of contact with electrolyte, rinse eyes immediately with plenty of water. Consult

a doctor.

Observe the following:

  Observe the polarities (+/-).

  The batteries must be new and undamaged.

  Do not mix new and used batteries.

Store, transport and dispose of the batteries in compliance with local requirements, regula-
tions and laws. Also observe the instructions of the battery manufacturer.

Mounting

The SSA911.01ZB is mounted on the radiator valve. There are no preferred mounting posi-
tions; the actuator SSA911.01ZB may be operated in all mounting positions. Make sure the
display is visible and the buttons are accessible.

WARNING

Falling objects

Overhead installation may result in injury from falling objects.

  Do not install the actuator more than 2 m above ground.

Firmly tighten the screw nut by hand. No tools are required to tighten the actuator on the
valve.

Commissioning

  Install the mobile application Connected Home.

–  The app provides a step-by-step guide through the commissioning process.

  Install and commission Connected Home Hub GTW100ZB (see also quick guide

A6V12694180).

  Optional: Install and commission Connected Home Receiver RCR110.2ZB (see also

quick guide A6V11562443).

  Install and commission Connected Home Radiator Valve SSA911.01ZB (see app, quick

guide A5W00205935A).

Summary of Contents for SSA911.01ZB

Page 1: ...bidi rectional Connection and operation with Connected Home Hub and Receiver Battery powered by commercially available 1 5 V AA batteries Valve thread connection M30x1 5 mm Nominal stroke 5 mm Valve positioning force 90 N Automatic adaptation to valve Integrated temperature sensor and PI controller Temperature settings either on the device or via the app A6V12789814_en _a Smart Infrastructure 2022...

Page 2: ...nge of the network Siemens Connected Home Application GTW100ZB SSA911 01ZB RCR110 2ZB Basic functions Function Description Communication The communication protocol used is ZigBee ZigBee is a low power wireless mesh networking protocol and enables device to device and device to cloud communication ZigBee is based on IEEE 802 15 4 radio standard Parallel operation Up to 32 actuators can be paired an...

Page 3: ...MCV MiniCombiValves 10 135 A6V13089932 VD1 VE1 Radiator valves 0 25 3 4 N2145 VD2 VE2 VU2 N2146 kVS Nominal flow rate of chilled water 5 30 C through the fully opened valve H100 at a differential pressure of 100 kPa 1 bar V Volumetric flow No longer available Third party valves without adapter The SSA911 01ZB can operate third party radiator valves without adapter provided they have a M30x1 5 mm c...

Page 4: ... For use with Adapter thread AV52 BPZ AV52 Comap M28x1 5 AV56 BPZ AV56 Giacomini AV57 BPZ AV57 Herz M28x1 5 AV58 BPZ AV58 Oventrop 2002 M30x1 AV59 BPZ AV59 Vaillant AV60 BPZ AV60 TA 2002 M28x1 5 AV61 BPZ AV561 MMA Markaryd M28x1 5 For information on adapters for other radiator valve types and manufacturers contact your local office or branch ...

Page 5: ...product description A6V12680327 Quick guide Connected Home Receiver RCR110 2ZB Quick instructions for mounting commissioning and operating RCR110 2ZB A6V11562443 Related documents such as environmental declarations CE declarations etc can also be downloaded at the following Internet address www siemens com bt download Notes Security CAUTION National safety regulations Failure to comply with nation...

Page 6: ...la tions and laws Also observe the instructions of the battery manufacturer Mounting The SSA911 01ZB is mounted on the radiator valve There are no preferred mounting posi tions the actuator SSA911 01ZB may be operated in all mounting positions Make sure the display is visible and the buttons are accessible WARNING Falling objects Overhead installation may result in injury from falling objects Do n...

Page 7: ... immediately and raise by another 0 5 every 0 5 s while button is pressed or until the highest temperature is reached Press once Perform the displayed function LED Red Blinking Update of controller software is being performed no temperature regulation possible Shining Commissioning error Green Blinking Waiting for confirmation by user used to start tasks Shining 5 s Task successfully completed Pre...

Page 8: ...oom temperature After 15 min function stops OFF mode automatically and last active mode is restored Function can be manually stopped by pressing the okay button Error codes In case of an actuator malfunction or communication error with the Connected Home Hub an error code is shown on the display of the SSA911 01ZB The error codes ER1 ER3 can be cleared by pressing the okay button Code Error Cause ...

Page 9: ...ts systems machines and networks against cyber threats it is neces sary to implement and continuously maintain a holistic state of the art security concept Siemens portfolio only forms one element of such a concept You are responsible for preventing unauthorized access to your plants systems machines and networks which should only be connected to an enterprise network or the internet if and to the...

Page 10: ...on power 8 dBm Range 30 m depending on application and building Protocol ZigBee Actuator Stroke 5 mm Positioning force typically 90 N Noise level EN ISO 3741 30 dBA Built in temperature sensor Measuring range 0 50 C Internal controller Type PI Degree of protection Protection class Class III according to IEC 60730 1 Protection degree of housing IP 20 1 according to IEC 60529 Pollution degree Class ...

Page 11: ... of use For residential commercial and industrial environments EU conformity CE A5W00090263A 2 EAC compliance Eurasian compliance for SSA911 01ZB Environmental compatibility Product environmental declarations A6V13096860 2 include data on environmentally friendly product design and testing RoHS compliance material composition packaging environmental benefits disposal Materials and Dimensions Displ...

Page 12: ...A103 01 Issued by Siemens Switzerland Ltd Smart Infrastructure Global Headquarters Theilerstrasse 1a CH 6300 Zug 41 58 724 2424 www siemens com buildingtechnologies Siemens Switzerland Ltd 2022 Technical specifications and availability subject to change without notice Document ID A6V12789814_en _a Edition 2022 02 14 ...