background image

1

 

UL listed

 

Rated for single phase panels up to 400 amps

 

Installation flexibility

 

Audible Alarm

 

Internal diagnostics keep you informed

 

Guaranteed lightning protection

 

10-year product warranty*

Siemens  SPD4home  shields  motor-driven  appliances  in  residential  and  light 
commercial  applications  against  electrical  power  surge  damage,  including 
lightning, from entering through the main electrical service panel.

Multiple  MOV  technology  with  thermal  disconnect  to  prevent  catastrophic 
failure. The two LED lights indicate protection status. The audible alarm alerts 
you when protection is disrupted.

Total Home Surge Protection 

SPD

4

home

Surge Protection for Point-of-Entry

Features and Benefits 

User Manual - US

A

 

Eng

lish

 

Technical Specifications

AC SURGE PROTECTION
Thermal Fusing 

Yes

Catastrophic Surge Circuit

Yes

Single Pulse Energy Dissipation

1080 Joules

Spike Capacity 

40,000A

Line Voltage

120/240 1 Phase 50/60 Hz

VPR MCOV

700V

Rated Voltage

150V

Response Time

<1 nanosecond

Short Cicuit Rating

25,000A

NEMA 4X Enclosure

Standard

AGENCY APPROVALS & WARRANTY
UL/cUL Listings**

1449 SPD

Meets IEEE C62.41.1 Requirements  Yes
Product Warranty

10 Years

CATALOG NUMBER
SPD4home

Point-of-Entry Protector

UL Model No. - TPSA9040

* See www.usa.siemens.com/spd for warranty details.

Summary of Contents for SPD4home

Page 1: ...s SPD4home User Manual Manuel d Installation ...

Page 2: ......

Page 3: ...Table of Contents User Manual USA English 1 User Manual Canada English Anglais 5 Manuel d installation Canada Français French 7 s ...

Page 4: ......

Page 5: ...s USA www usa siemens com spd ...

Page 6: ......

Page 7: ...tus The audible alarm alerts you when protection is disrupted Total Home Surge Protection SPD4home Surge Protection for Point of Entry Features and Benefits User Manual USA English Technical Specifications AC SURGE PROTECTION Thermal Fusing Yes Catastrophic Surge Circuit Yes Single Pulse Energy Dissipation 1080 Joules Spike Capacity 40 000A Line Voltage 120 240 1 Phase 50 60 Hz VPR MCOV 700V Rated...

Page 8: ...gnator L1 or L2 Connect the SPD 4home leads to the appropriate phases In all installations it is not critical which black wire goes to the positions on the circuit breaker Connect the white Neutral wire to the neutral bar using a set screw in some applications this connection may not be required Connect the green Ground wire to the panelboard ground 8 Install the panelboard cover Note Conducting d...

Page 9: ...s Canada www purgethesurge ca ...

Page 10: ......

Page 11: ...The audible alarm alerts you when protection is disrupted Technical Specifications AC SURGE PROTECTION Thermal Fusing Yes Catastrophic Surge Circuit Yes Single Pulse Energy Dissipation 1080 Joules Spike Capacity 40 000A Line Voltage 120 240 1 Phase 50 60 Hz VPR MCOV 700V Rated Voltage 150V Response Time 1 nanosecond Short Cicuit Rating 25 000A NEMA 4X Enclosure Standard AGENCY APPROVALS WARRANTY U...

Page 12: ...e following connections to be made see Figure 1 Black wires go to the nearest free 20 Amp 2 pole circuit breaker The phase of each lead is marked with a white band and letter designator L1 or L2 Connect the SPD 4home leads to the appropriate phases In all installations it is not critical which black wire goes to the positions on the circuit breaker Connect the white Neutral wire to the neutral bar...

Page 13: ...L indiquent l état de protection L alarme sonore prévient lorsque la protection est perturbée Données techniques Limiteur général de surtension SPD4home SPD4home pour tableau résidentiel Caractéristiques et avantages Manuel d installation Canada Français French PROTECTION CONTRE LES SURTENSIONS C A Fusible thermique Oui Circuitantisurtensioncatastrophique Oui Dissipationd énergiemonoimpulsion 1080...

Page 14: ...s La phase de chaque fil est indiquée par une bande blanche et un code L1 ou L2 Brancher les fils du SPD4home aux phases qui conviennent l un ou l autre des fils noirs peut être raccordé à l une ou l autre des bornes du coupe circuit Connecter le conducteur neutre blanc à la barre neutre au moyen d une vis de blocage cette connexion n est pas nécessaire dans certaines installations Raccorder le co...

Page 15: ......

Page 16: ...11 7 11 888 333 3545 s ...

Reviews: