The dishwasher must be connected
correctly, otherwise it will not function
properly. The specifications for the inlet
and outlet as well as the electrical
connected loads must correspond with the
required criteria as specified in the
following paragraphs or in the installation
instructions.
Install the appliance in the correct
sequence:
–
Checking appliance on delivery
–
Installing the appliance
–
Waste water connection
–
Fresh water connection
–
Electrical connection
Safety instructions
–
Install and connect the appliance
according to the installation and
assembly instructions.
–
Prior to installation, disconnect the
dishwasher from the power supply.
–
Ensure that the protective conductor
system of the domestic supply has
been correctly installed.
–
The electrical connection conditions
must correspond with the
specifications on the dishwasher rating
plate
1b
.
–
If the power cord of this appliance is
damaged, it must be replaced with
a particular power cord.
To prevent injury, the power cord
may be replaced by customer service
only.
–
If the dishwasher is installed in a high-
sided unit, the unit must be secured
properly.
–
Do not install the appliance near heat
sources (radiators, heat storage tanks,
cookers or other appliances which
generate much heat) and install
it under a hob only in consideration
of the stipulated safety clearances.
–
After installing the appliance, ensure
that the plug is easily accessible.
–
Some models:
The plastic housing on the water
connection contains an electric valve,
the connecting cables are in the supply
hose. Do not cut through this hose,
do not immerse the plastic housing in
water.
Delivery
Your dishwasher has been checked
thoroughly in the factory to ensure that it is
in working order. This may cause small
water stains. These will disappear after the
first wash cycle.
Technical specifications
Weight:
max. 24 kg
Voltage:
220–240 V, 50 Hz or 60 Hz
Connected load:
1.9–2.3 kW
Fuse:
10/16 A
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing valve
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water; hot water max. temperature
60 °C.
Installation