Scale parameters and functions
8.24 DR 46 protocol contents
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
127
Variable
Note
Type
Length
(bytes)
Rw
Default
Min. Max.
Modbus
registers
Delimiters
Delimiter (semicolon)
CHAR
1
r
";"
Tare
Currently effective tare
CHAR[8]
8
r
" "
String header for
checksum
String header for checksum
UBYTE[2] 2
r
4.4
CRC16 checksum
Checksum of selected protocol CHAR[4]
4
r
"0000"
6146
String header for
date
String header for date
UBYTE[2] 2
r
10.10
6147
Date
Date
CHAR[10] 10
r
"2012-03-
31"
6150
String header for
time
String header for time
UBYTE[2] 2
r
8.8
6155
Time
Time
CHAR[8]
8
r
"23:59:59"
6156
String header for
supplementary in-
formation
String header for supplementary
information
UBYTE[2] 2
r
2.2
6100
Supplementary info
Currently not used
CHAR[4]
4
r
" "
6161
Reserve
Reserve
USHORT 2
r
0
6163
1)
The protocol string is read out as a unit over Modbus (Modbus registers 6132 ... 6145)
8.24.2
Oldest protocol ID
The ID of the first saved protocol is displayed here.
8.24.3
Newest protocol ID
The ID of the last saved protocol is displayed here.
8.24.4
Selected protocol ID, numeric
The ID of the protocol requested in data record 45 and shown in data record 46 is displayed
here.
8.24.5
Gross / net identifier
The identifier provides information on whether a gross weight or net weight was logged for
the selected ID.
8.24.6
G/N weight
The G/N weight of the selected log is displayed here.
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...