4BWEIGHING FUNCTIONS
5.8.5
DR 31/32 – operating errors
In the 16 bits the pending operating errors are displayed.
Bit no.
Name
Remarks
0
1= limit for load cell signal exceeded or undershot
See message list Chapter
1
1= minimum voltage at the sense line undershot
See message list Chapter
2
1=
watchdog
See message list Chapter
3
1= error in EPROM
See message list Chapter
4
1= error in EEPROM
See message list Chapter
5
1= error in RAM
See message list Chapter
6
1= ADC error
See message list Chapter
7
1= number overflow in weight calculation
See message list Chapter
8
1= No 24 V supply
See message list Chapter
9
Reserve
Table 5-8
Operating errors
5.8.6
DR 31/32 – data and command errors
In the 16 bits, the data or command errors which occurred most recently are
displayed. The display is reset at the next command or next data transfer.
Bit no.
Name
Remarks
0
1= adjustment command could not be executed as distance
between adjustment points is too small
See message list Chapter
1
1= instruction could not be executed due to fault
See message list Chapter
2
1= a non-existent or inactive channel was addressed
See message list Chapter
3
1= code not defined (e.g. cutoff frequency, digital filter etc.)
See message list Chapter
4
1= data record/command unknown
See message list Chapter
5
1= command not possible because scale is not adjusted
See message list Chapter
6
1= waiting time of 5 sec. for adjustment commands not
observed
See message list Chapter
7
1= the adjustment weight is negative
See message list Chapter
9 Reserve
Table 5-9
Data or command errors
5.9 DR 40 module info
No entries can be made in DR40. The purpose of the data record is to provide
information about the module version.
Name
Model
Length
Default
Range of Values / Meaning / Display
FW version
WORD
2
Firmware version
FW checksum
WORD
2
0…..65535
Reserve
BYTE
1
0
Reserve
Number of channels
BYTE
1
1/2
Number of channels
Model
BYTE
1
1/0
0= 7MH4601...., 1= 7MH4950.....
Reserve
BYTE
1
0
Reserve
8
Table 5-10
Allocation of DR 40
SIWAREX U
5-39
Summary of Contents for Siwarex U
Page 8: ......