Weighing Functions
SIWAREX FTA
5-116
Name
Type
Address Range of Values / Explanation
Reference
Statistic data
Total number of
weightings
DINT
DBD000
Number of weighing procedures (with and
without tolerance check)
Number of control weighs
DINT
DBD004 Number of weighing procedures with
tolerance check
Number of weighing
procedures over TO2
DINT
DBD008 Number of weighing procedures with
tolerance check over tolerance limit TO2
No. weigh procedures over
TO1
DINT
DBD012 Number of weighing procedures with
tolerance check over tolerance limit TO1
Number of weighing
procedures good
DINT
DBD016 Number of weighing procedures with
tolerance check within tolerance limits TU1
to TO1.
No. weigh procedures
under TU1
DINT
DBD020 Number of weighing procedures with
tolerance check under tolerance limit TU1
No. weigh procedures
under TU2
DINT
DBD024 Number of weighing procedures with
tolerance check under tolerance limit TU2
Number of weighing
procedures bad
DINT
DBD028 Number of weighing procedures with
tolerance check outside tolerance limits TU2
or TO2
Reserve 0
DINT
DBD032 Reserve 0
Reserve 1
DINT
DBD036 Reserve 1
Set weight
REAL
DBD040 Current set weight (calibratable numeral
step,
with AWI application and country code
“OIML” rounded to the corresponding
numeral step)
Average value of net
weight
REAL
DBB044 Average value of the net weights checked
for tolerance errors
Standard deviation of net
weights
REAL
DBB048 Standard deviation of the net weights
checked for tolerance errors
Performance per hour
REAL
DBB052 Performance per hour [e.g. g/h, kg/h or t/h]
is projected based on the net weight of the
last weighing procedure.
Weighing procedures per
hour
INT
DBW056 Weighing procedures per hour projected
based on the last weighing procedure (time
for one weighing cycle).
58
Table 5-22
DR 32 Allocation
5.21.1 DR 32 - Total number of weighing procedures
Number of weighings since the last statistic data deletion. The number of single fills
is determined in all operating modes.
5.21.2 DR 32 - Number of control weighs
The number of weighings in which a tolerance check has been performed. In
operating modes with totalizing (AWI totalizing and AWI gravimetric big bag),
the total loadings are counted.