Technical specifications

SITRANS P250 (7MF1641) Technical data 
Applications  
Differential pressure 

measurement  

Liquids and neutral gases  

Mode of operation  
Measuring principle  

Piezoresistive measuring cell (ceramic diaphragm)  

Input  
Measured variable  

Differential pressure  

Measuring range  

0 ... 0.1 to 0 ... 25 bar 
(0 ... 1.45 to 0 ... 363 psi) 
≤ 25 bar at a differential pressure range < 6 bar 

Operating pressure  

≤ 50 bar at a differential pressure range > 10 bar 

Burst pressure  

1.5 x system pressure  

Output  
Output signal  

 

Current output signal 

4 ... 20 mA  

 

Voltage output signal 

0 ... 5 VDC and 0 ... 10 VDC  

Load  

 

3-wire 

> 10 kΩ  

 

2-wire 

≤ (UH - 11 V) / 0.02 A  

Measuring accuracy  
Dynamic behavior  

(at 25°C / 77°F, including 

conformity error, hysteresis, 

and repeatability)  

≤ 1% of full scale value - typical,  

see table " Maximum permitted pressure ranges" 

Long-term drift in accordance 

with IEC 60770  

≤ 0.5 % of full scale value 

Ambient temperature influence  

 

Start of scale value 

≤ 0.6 % / 10K of full scale value (≤ 1.2 % / 10K with 

measuring cell 0 ... 0.1 bar (1.45 psi))  

 

Full scale value 

≤ 0.22 % / 10K of full scale value (≤ 0.37 % / 10K with 

measuring cell 0 ... 0.1 bar (1.45 psi))  

Dynamic behavior  

Suitability for static and dynamic measurements  

Response time T99  

< 5 ms  

Load alternation  

< 50 Hz  

Conditions of use 
Ambient conditions 

 

 

Process temperature 

- 15 ...+ 85 °C (5 ... 185 °F) 

 

Ambient temperature 

- 15 ...+ 85 °C (5 ... 185 °F) 

 

Storage temperature 

- 40 ...+ 85 °C (-40 ... +185 °F) 

Degree of protection to 

EN 60529 

IP65 

Mounting position 

Any  

Installation 

Fastening bracket, included 

Construction 
Weight  

approximately 430 g (c. 0.95 lb)  

Housing material  

Stainless steel 1.4305/AISI 303 m  

Electrical connection 

 

Plug connector DIN EN 175301-803-A 

 

Round plug DIN EN 60130-9 

 

Cable 1.5 m 

Process connection  

 

Hose tailpiece Ø 4 mm/6 mm 

 

Pipe union Ø 6 mm/ 8 mm 

 

Male thread 7/16-20 UNF, G1/8 

 

Female thread 1/8-27 NPT (standard), G1/8 

Material of the wetted parts  

 

Process connection 

Stainless steel 1.4305/AISI 303, CuZn nickel-plated  

 

Diaphragm 

Ceramics Al2O3 (96 %)  

 

Sealant 

FPM (standard), EPDM, NBR, MVQ, CR 

Auxiliary power 
UH Terminal voltage on pressure transducer  

 

2-wire, 4 ... 20 mA 

11 ... 33 VDC  

 

3-wire, 0 ... 5 VDC 

11 ... 33 VDC/24 VAC ± 15 %  

SITRANS P250 (7MF1641) Technical data 

 

3-wire, 0 ... 10 VDC 

18 ... 33 VDC/24 VAC ± 15 %  

Current consumption at rated pressure  

 

2-wire 

< 20mA  

 

3-wire 

< 5mA  

Reverse polarity protection  

Short circuit and reverse polarity protected Every 

connection to every other one with max. supply 

voltage.  

Certificates and approvals 
Approval  

CE conformity  

Maximum permissible pressure ranges 

Measuring range 

Maximum permitted operating 

pressure  

[bar] 

[psi] 

(at one side) 

(at both sides) 

Burst 

pressure 

Deviating 

measurement  

0... 0,1  0...1.45  0.6 bar 

(8.7 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 1,0 %  

0... 0,2  0...2.9 

0.6 bar 

(8.7 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,8 %  

0... 

0,25 

0...3.63  0.6 bar 

(8.7 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,5 %  

0... 0,3  0...4.35  0.6 bar 

(8.7 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,5 %  

0... 0,4  0...5.8 

1.2 bar 

(17.4 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,8 %  

0... 0,5  0...7.25  1.2 bar 

(17.4 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,5 %  

0... 0,6  0...8.7 

1.2 bar 

(17.4 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,5 %  

0... 1,0  0...14.5  2 bar (29 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,5 %  

0... 1,6  0...23.2  3.2 bar 

(46.4 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,5 %  

0... 2,5  0...36.3  5 bar 

(72.5 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,5 %  

0... 4 

0...58 

8 bar (116 psi)  25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,5 %  

0... 6 

0...87 

12 bar 

(174 psi) 

25 bar (363 psi)  37.5 bar 

(544 psi)  

≤ 0,5 %  

0... 10 

0...145 

20 bar 

(290 psi) 

50 bar (725 psi)  75 bar 

(1088 psi)  

≤ 0,5 %  

0... 16 

0...232 

32 bar 

(464 psi) 

50 bar (725 psi)  75 bar 

(1088 psi)  

≤ 0,5 %  

0... 25 

0...363 

50 bar 

(725 psi) 

50 bar (725 psi)  75 bar 

(1088 psi)  

≤ 0,5 %  

Summary of Contents for SITRANS P250

Page 1: ... 0 to 5 V DC or 0 to 10 V DC three wire technology Installation The location of the device has no influence on the precision of the measurement Before installation compare the process data with the data of the rating plate The medium being measured must be suitable for the parts of the pressure transmitter in contact with the medium The burst pressure must not be exceeded The following operating c...

Page 2: ...Stabilizing valve Mounting Electromagnetic compatibility Interference immunity Test standard Effect Electrostatic discharge ESD EN 61000 4 2 8 kV air 6 kV contact No failure High frequency electromagnetic irradiation HF EN 61000 4 3 3 V m 80 MHz to 3 GHz No influence Grid bound HF EN 61000 4 6 10 V 0 15 to 80 MHz No influence Quick transient burst EN 61000 4 4 2 kV No failure Power surge EN 61000 ...

Page 3: ... Cable 1 5 m Process connection Hose tailpiece Ø 4 mm 6 mm Pipe union Ø 6 mm 8 mm Male thread 7 16 20 UNF G1 8 Female thread 1 8 27 NPT standard G1 8 Material of the wetted parts Process connection Stainless steel 1 4305 AISI 303 CuZn nickel plated Diaphragm Ceramics Al2O3 96 Sealant FPM standard EPDM NBR MVQ CR Auxiliary power UH Terminal voltage on pressure transducer 2 wire 4 20 mA 11 33 VDC 3 ...

Page 4: ...nless steel 1 4305 AISI 303 8 a 12 b 14 26 67 L a 1 8 27 NPT G1 8 Female thread G1 8 stainless steel 1 4305 AISI 303 a 14 12 53 6 a 10 b 12 24 65 a b L 1 8 27 NPT Pipe union with screw in nipple for pipe external CuZn vni 8 a 12 b 14 25 66 4 20 61 a L 1 8 27 NPT Hose connection for hose CuZn vni stainless steel 1 4571 AISI 316TI 6 a 10 b 10 25 66 L b a 1 8 27 NPT Male thread G1 8 CuZn vni a 10 b 1...

Page 5: ...lossen werden Das Ausgangssignal beträgt wahlweise 4 bis 20 mA Zweileitertechnik 0 bis 5 V DC oder 0 bis 10 V DC Dreileitertechnik Montage Die Lage des Geräts hat keinen Einfluss auf die Messgenauigkeit Vergleichen Sie vor der Montage die Prozessdaten mit den Daten des Typschilds Der Messstoff muss für die messstoffberührten Teile des Druckmessumformers geeignet sein Der Berstdruck darf nicht über...

Page 6: ...auen Elektromagnetische Verträglichkeit Störfestigkeit Prüfnorm Auswirkung Elektromagnetische Entladung ESD EN 61000 4 2 8 kV Luft 6 kV Kontakt Kein Ausfall Hochfrequente elektromagnetische Einstrahlung HF EN 61000 4 3 3 V m 80 MHz 3 GHz Keine Beeinflussung Leitungsgebundene HF EN 61000 4 6 10 V 0 15 80 MHz Keine Beeinflussung Schnelle Transienten Burst EN 61000 4 4 2 kV Kein Ausfall Stoßspannung ...

Page 7: ...ten Prozessanschluss Schlauchstutzen Ø 4 mm 6 mm Rohrverschraubung Ø 6 mm 8 mm Außengewinde 7 16 20 UNF G1 8 Innengewinde 1 8 27 NPT Standard G1 8 Werkstoff der messstoffberührten Teile Prozessanschluss Edelstahl 1 4305 AISI 303 CuZn vernickelt Membrane Keramik Al2O3 96 Dichtmaterial FPM Standard EPDM NBR MVQ CR Hilfsenergie UH Klemmenspannung am Druckmessumformer 2 Leiter 4 20 mA DC 11 33 V 3 Lei...

Page 8: ...lstahl 1 4305 AISI 303 8 a 12 b 14 26 67 L a 1 8 27 NPT G1 8 Innengewinde G1 8 Edelstahl 1 4305 AISI 303 a 14 12 53 6 a 10 b 12 24 65 a b L 1 8 27 NPT Rohrverschraubung mit Einschraubnippel für Rohr außen CuZn vni 8 a 12 b 14 25 66 4 20 61 a L 1 8 27 NPT Schlauchanschluss für Schlauch CuZn vni Edelstahl 1 4571 AISI 316TI 6 a 10 b 10 25 66 L b a 1 8 27 NPT Außengewinde G1 8 CuZn vni a 10 b 12 20 61...

Reviews: