1  About this document

1.1 Function

This operating instructions manual provides all the information you 

need for mounting, connection and setup as well as important instruc-

tions for maintenance and fault rectification. Please read this informa

-

tion before putting the instrument into operation and keep this manual 

accessible in the immediate vicinity of the device.

1.2  Target group

This operating instructions manual is directed to trained specialist 

personnel. The contents of this manual should be made available to 

these personnel and put into practice by them.

1.3  Symbols used

Information, tip, note

This symbol indicates helpful additional information.

Caution:

 If this warning is ignored, faults or malfunctions can result.

Warning:

 If this warning is ignored, injury to persons and/or serious 

damage to the instrument can result.

Danger:

 If this warning is ignored, serious injury to persons and/or 

destruction of the instrument can result.

Ex applications

This symbol indicates special instructions for Ex applications.

SIL applications

This symbol indicates instructions for functional safety which must be 

taken into account particularly for safety-relevant applications.

• 

List

The dot set in front indicates a list with no implied sequence.

→ 

Action

This arrow indicates a single action.

1  Sequence of actions

Numbers set in front indicate successive steps in a procedure.

Battery disposal

This symbol indicates special information about the disposal of bat-

teries and accumulators.

Summary of Contents for Sitrans LVL200

Page 1: ...Operating Instructions 06 2016 Vibrating Switches Electronics module Sitrans LVL200 ...

Page 2: ...2 7ML19985LS31 Electronics module Operating Instructions 33997 EN 160621 ...

Page 3: ...priate use 5 2 3 Safety instructions for Ex areas 5 3 Product description 3 1 Configuration 6 3 2 Principle of operation 6 3 3 Packaging transport and storage 6 4 Mounting 4 1 Mounting instructions 7 4 2 Mounting preparations 7 4 3 Installation procedure 7 5 Setup 5 1 Setup 9 6 Maintenance 6 1 Instrument repair 10 7 Dismount 7 1 Dismounting steps 11 7 2 Disposal 11 8 Supplement 8 1 Technical data ...

Page 4: ...e This symbol indicates helpful additional information Caution If this warning is ignored faults or malfunctions can result Warning If this warning is ignored injury to persons and or serious damage to the instrument can result Danger If this warning is ignored serious injury to persons and or destruction of the instrument can result Ex applications This symbol indicates special instructions for E...

Page 5: ... operator During work on and with the device the required personal protective equipment must always be worn 2 2 Appropriate use The electronics module is a replacement module for Sitrans LVL200 vibrating level switches 2 3 Safety instructions for Ex areas Please note the Ex specific safety information for installation and op eration in Ex areas These safety instructions are part of the operating i...

Page 6: ...ompanies Transport must be carried out in due consideration of the notes on the transport packaging Nonobservance of these instructions can cause damage to the device The delivery must be checked for completeness and possible transit damage immediately at receipt Ascertained transit damage or con cealed defects must be appropriately dealt with Up to the time of installation the packages must be le...

Page 7: ...age under Downloads 4 3 Installation procedure To exchange the electronics module proceed as follows 1 Switch off power supply 2 Unscrew the housing lid 3 Lift the opening levers of the terminals with a screwdriver 4 Pull the connection cables out of the terminals 5 Loosen the two screws with a screw driver Torx size T10 or slot 4 2 1 Fig 1 Loosen the holding screws 1 Electronics module 2 Screws 2...

Page 8: ...olding screws and tighten them 11 Insert the wire ends into the open terminals according to the wir ing plan 12 Press down the opening levers of the terminals you will hear the terminal spring closing 13 Check the hold of the wires in the terminals by lightly pulling on them 14 Check cable gland on tightness The seal ring must completely encircle the cable 15 Screw the housing lid back on The elec...

Page 9: ... electronics module can be also exchanged within the type series against an electronics with another signal output e g relay against transistor output If you want to use an electronics module with a completely different signal output you have to carry out the complete setup The necessary suitable operating instructions manual can be down loaded from our homepage under Downloads The adjustment shou...

Page 10: ...ng Instructions 33997 EN 160621 6 Maintenance 6 1 Instrument repair If it is necessary to repair the instrument please contact Siemens Milltronics Process Instruments Inc You find the locations on our homepage www siemens com processautomation ...

Page 11: ...E directive 2002 96 EG This instrument is not subject to the WEEE directive 2002 96 EG and the respective national laws in Germany e g ElektroG Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points These may be used only for privately used products according to the WEEE directive Correct disposal avoids negative effects on humans and the ...

Page 12: ...12 7ML19985LS31 Electronics module Operating Instructions 33997 EN 160621 8 Supplement 8 1 Technical data Technical data are stated in the operating instructions manual of the respective sensor ...

Page 13: ...Notes 13 7ML19985LS31 Electronics module Operating Instructions 33997 EN 160621 ...

Page 14: ...Notes 14 7ML19985LS31 Electronics module Operating Instructions 33997 EN 160621 ...

Page 15: ...Notes 15 7ML19985LS31 Electronics module Operating Instructions 33997 EN 160621 ...

Page 16: ...x 4225 Peterborough ON K9J 7B1 Canada email techpubs smpi siemens com www siemens com processautomation Subject to change without prior notice 7ML19985LS31 Rev 0 0 Siemens AG 2016 For more information www siemens com level www siemens com weighing Printed in Canada ...

Reviews: