Installation
4
Ideal Locations
●
areas where the acoustic emission levels are highest and most consistent
●
where the material impact is greatest
●
areas closest to the point of leakage (e.g. valve body)
●
closest point to source of cavitation (e.g. pump body)
Conditions to Avoid
●
non-metallic surfaces, as these tend to attenuate acoustic emission levels
●
pipes with non-metallic liners as these tend to attenuate acoustic emission levels
Conditions to Consider
●
joints and interfaces attenuate the acoustic emission levels.
●
minimal temperature variation where acoustic emission levels are weak.
●
location should provide sufficient response time in alarm or control circuit. e.g. loss of bearing
lubrication, plug chute detection.