Channel 6:
Chart 14 Input channel 6 (CH6)
Specifications at TA=25ºC; Test conditions U
S
= 24V DC (rated Voltage);
unless otherwise noted;
1)
not allowed;
2)
overshoot is leading to demolition;
3)
only allowed for appropriate
IEPE-sensors
4)
with connected sensors by Power-Up;
5)
Pulling an pushing the sensors under voltage
Measurement input
Parameter
min.
typ.
max.
unit
Input voltage (DC)
Rated voltage
± 30
V
Input resistance
50
k
Ω
Input frequency
0 (DC)
1
kHz
Coupling inputs
DC
Cross talk attenuation (CTA)
Channel to channel @ f = 1kHz;
-78
dB
Signal to noise ratio (SNR)
-69
dB
Sampling rate
each channel
192
kSPS
Down sampling rate
to parameterize with “X-Tools”
4 / 8 / 16 / 24 / 32 / 48 / 96
kSPS
4
96
kSPS
Accuracy
Abs. (based on full scale)
± 1
%
Temperature dependency
- 125
+ 83
ppm/K
Galvanic isolation
no
Rise time
from 10% to 90% of rated voltage
16
us
Cable break detection
no
Cable short detection
no
SIPLUS CMS4000 IFN VIB-A
Operating Instructions, 11/2014, A5E02297871A-AA