Programming support
3.3 Activating a dialog from the NC program
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
3-7
3.3.2
Example of MMC instruction
MMC instruction in the parts program
MMC("CYCLES,PICTURE_ON,T_SK.COM,PICTURE1,MGUD.DEF,PICTURE3.BMP,
TEST_1,A1","S")
CYCLES
Operating area
PICTURE_ON
Select dialog
T_SK.COM
File name in cycle directory
PICTURE1
Name of the dialog
MGUD.DEF
User data definition file
PICTURE3.BMP
Name of graphics file (HMI Advanced only)
TEST_1
Acknowledgment variable (HMI Advanced only)
or display time in "N" mode
A1
Screen header or comment from a text variable (COM file)
S
Acknowledgment mode: Synchronized
User variables in definition directory
%_N_UGUD_DEF
;$PATH=/_N_DEF_DIR
DEF CHAN REAL TEST_1
CHAN
Applicable channel
REAL
Data type
TEST_1
Name of user variable
Dialog screen file in the cycles directory (*.COM)
//C3(Screen2)
R/ 15 75 / 5 /COMMENT, %1 %2 %3/ W,RJ / TEST_1 / ...
R
Variable Type: Real, Integer or String
15 75
Permissible range: 15 to 75
5
Default setting for user variable
COMMENT, %1 %2 %3
Comment text with optional text variables
W,RJ
Access
type:
W = Read and write
R = Read-only
W, RJ = Read and write with comment
J = Right-justified in relation to input/output field
<without> = Left-justified in relation to input/output
field
TEST_1
User variable
Summary of Contents for SINUMERIK
Page 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Page 96: ......
Page 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Page 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...