Basic logic functions: Travel to fixed stop (F1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
7
Detailed Description
2
2.1
General functionality
2.1.1
Functional sequence, programming, parameterization
Programming
Travel to fixed stop is selected or deselected with the following commands:
FXS[Machine axis identifier]=1
(selected)
FXS[Machine axis identifier]=0
(deselected)
The commands are modal.
The clamping torque is set with command:
FXST[Machine axis identifier] = <Torque>
adjusted.
It is in % of the static torque for VSA of the drive:
(MD1118 MOTOR_STANDSTILL_CURRENT)
or in % of the engine torque for HSA drives:
(MD1130 MOTOR_NOMINAL_POWER)
entered.
The command is used for setting the width of the fixed stop monitoring window.
FXSW[machine axis identifier] = monitoring window
The unit is dependent on the default setting: mm, inch or degrees.
Summary of Contents for SINUMERIK 840D sl
Page 282: ...Index Basic logic functions Acceleration B2 64 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 388: ...Basic logic functions Travel to fixed stop F1 Function Manual 11 2006 6FC5397 0BP10 2BA0 52 ...
Page 962: ...Index Basic logic functions Emergency Stop N2 20 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1704: ...Constraints Basic logic functions Spindles S1 94 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1716: ...Index Basic logic functions Spindles S1 106 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 1996: ...Index Basic logic functions Tool Offset W1 208 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2150: ...Table of contents Basic logic functions Appendix 4 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...
Page 2184: ...Glossary Basic logic functions Appendix 38 Function Manual 11 2006 6FC5397 0BP10 2BA0 ...